Close AvocAudio Lid
Table
| Quantity | Part and durable source | Current state |
|---|---|---|
| 1 | 3D Model | Unchanged R2.1; one solid, 44084.8231 mm³; installation/support blockers below |
| 1 | 3D Model | Current corrected source; one valid solid, 17425.4842 mm³, 61×80×20.4 mm, 218 faces |
| 1 | 3D Model | Unchanged approved R3.1; one solid, 10723.4558 mm³; bearing gap remains |
| 1 | 3D Model | 42.6×3×13.6 mm; no engineered retention, glands or seal |
| 8 | 3D Model | Existing simplified M2×6 socket-head concept, smooth shank; purchase specification not released |
| 8 | 3D Model | Existing simplified Series29 Short M2 intent, OD3.63×3.18; installation not qualified |
| 2 in 1 asset | 3D Model | Nominal 0.1 mm peripheral clearance; no bonding/seal/retention design |
| 1 | 3D Model | NONPRINTABLE 42×62×14 mm supplied-pack envelope, not restraint |
| 1 compound | 3D Model | NONPRINTABLE planning envelopes, not actual cables or assembled connector models |
| 2 active markers | 3D Model | Disks only, no shanks or threads; NOT functional PCB fasteners |
F1 closed assembly
F1 open assembly with actual PCB
document_assets/avocaudio-a-tinyml-community-board-v1-83e2d2b8cda83b01dfa30f2902e74430.glb. Open scene: document_assets/avocaudio-a-tinyml-community-board-v1-1c4914a80b845cefa7d2701236a45b5c.glb.Table
| Check | Result / severity | Evidence or specific blocker |
|---|---|---|
| S3/S4 base/service fit | PASS | Exact final-source intersection<1e−5 mm³; stated side clearance≥0.2999 mm |
| Service screw-seat bearing | PASS geometry; Warning strength unverified | Four contact regions atZ13.6;2.6 mm solid seat thickness; no torque, creep or load test |
| Single printable-body geometry | PASS F1 geometry | Pipeline reports one valid service solid; base/hatch remain prior single solids; does not establish assembly readiness |
| Approved appearance/branding | PASS | Same external envelope and0.5 mm recess; closed native render; low charcoal contrast noteworthy |
| PCB and electronics preservation | PASS scoped mutation/readback | No electrical, board, pad or component edits; final layout still42×57,R3,JLC7628 four-layer; original component models retained |
| PCB support/retention | FAIL / Error | Four support rings terminate at undersideZ−1.5162 but two retention disks have no shanks/threads. Safe underside landings/head access not certified. Maximum longitudinal span50.3575 mm exceeds50 mm guideline; no qualified centre support or locators |
| Insert installation and roots | FAIL / Error | Existing pocketsØ3.63 equal model OD, not qualified heat-set interference bores; lowerØ3.2×1 mm relief is not the full installation pocket. Column radial material around upper pocket≈1.235 mm; root/installation/load design not qualified. Do not install based on visual fit |
| Hatch screw bearing | FAIL / Error | Original pad bottom13.8 vs column top13.6 leaves0.2 mm gap. Only service seats were corrected |
| Screw nominal stack | PASS dimensional model only / Warning | Existing headØ3.8×2, hex1.5, nominal shaftØ2×6; seatsZ16.2, insert top13.6/bottom10.42, screw tip10.2, lower relief to9.42. Actual threads, tolerances, seating and tightening torque unverified |
| Maximum pack static fit | PASS limited | 42×62×14 block X[−72,−30],Y[−28,34],Z[−5.5,8.5] has<1e−5 mm³ intersection with tested base/service solids |
| Independent battery extraction | PASS envelope only / Warning | Vertical continuationZ8.5…48.5 clear of tested base/service; actual leads, disconnect/grip and removal operation unverified |
| Battery restraint/swelling | FAIL / Error | No engineered positive restraint or swelling allowance; pull-tab/disconnect remain proxies. Purchased harness/polarity unverified; do not clamp or compress pouch |
| Cable corridor reservations | PASS limited / Warning | All eight documented box corridors clear of exact base/service; actual connector bodies, wires, bend radii, strain relief and service travel NOT VERIFIED |
| Top/bottom assembly clearance | NOT VERIFIED / Warning | 2 mm planning margins reference estimated topZ14 and underside-envelopeZ−4.5, not measured finished assembly extrema; through-hole solder/tails matter |
| Underside microphone core | PASS geometry only | ExistingPCBØ1.1 hole at(−11.789,2.6135); enclosure nominalØ2 core; testedØ1.8 passage clear overZ−8.3…−2.3. Acoustic response, membrane, gasket and full installed path NOT VERIFIED |
| Weatherproof interfaces | FAIL / Error | Blank cable panel and lenses lack retention/seals; glands unspecified; seam tongue/gasket and acoustic membrane absent. No IP/rain/dust/weatherproof claim |
| ASA print fits/details | NOT VERIFIED / Warning | Printer, calibration, shrinkage, supports, fine logo groove reproduction and1.9 mm engraved roof strength unqualified |
| Thermal/charging safety | NOT VERIFIED / Warning | No full power/thermal assessment or verified pack charge-temperature protection; no outdoor unattended-charge approval |
| Full assembly collision inspection | NOT VERIFIED / Warning | Only exact base/service and stated envelope tests passed. Not a full PCB/hatch/hardware/harness/seal all-pairs collision proof |
| STEP retrieval | PASS availability; inspection NOT VERIFIED | F1 conversion returned1,007,929-character STEP source; first1000 characters showISO10303/AP214 advanced B-rep header. No complete imported STEP solid/assembly inspection; do not describe header read as CAD validation |
| Final scene restoration | PASS readback | F1 source attached, all11 temporarily hidden nodes re-enabled, original lifted transforms restored; eight inserts remain present and enabled by default |
| Browser editor | FAILED infrastructure / Info | Requester frontend unavailable; native server-side captures and project mutations succeeded |
efe48c21-3718-4644-9ab6-dbfd7390bae8 references avocaudio-f1-service.build123d; base 5453dde5-0039-4d89-a62f-0de50bc827ee and hatch dcd22c16-d2f5-44fb-9484-74ee041a440b unchanged. Hardware remains separate. Source validation reconstructs base for checks only; there is no hidden duplicate exported base.Table
| Assigned check | Disposition and evidence |
|---|---|
| Service-column correction | PASS source/evidence review; independent numeric rerun NOT VERIFIED. R3.35 cuts at S3/S4 end at Z13.6 around R3.05 columns. Current code checks old overlap≈5.1271, final overlap<1e−5, side-window distance≥0.2999 and no removal in the exterior1.8 mm band. No contradictory geometry found. |
| Service bearing seats | PASS nominal/source review. Four annular additions begin Z13.6, overlap old pads by0.1 mm, retain holes/counterbores, and establish2.6 mm to the Z16.2 head seat. Code tests material above/below contact and2.59 mm through-seat samples; torque/creep remains NOT VERIFIED. |
| Approved branding/silhouette | PASS scoped source/preview review. Service roof remains Z18.4 with0.5 mm subtraction to17.9; hatch still uses R3.1 source with36 contours/553 vertices/8 holes and cut-only engraving. No alternate hatch/source substitution or visible silhouette change found. Fine printed reproduction/strength NOT VERIFIED. |
| Source/node alignment and exploded restoration | PASS direct readback. Service efe48c21-3718-4644-9ab6-dbfd7390bae8 references the exact F1 source below, ROOT position(−21,0,79.7994), active, identity rotation, scale1. Base/hatch retain R2.1/R3.1 at(−21,0,0). Lenses active at Z77.7994; S1–S4 active with computed Z95.9994. Eight separate screw and eight insert nodes are enabled; insert tops Z13.6. Old main lid/four main markers disabled. Installed service position is Z0, not the lifted presentation. |
| PCB preservation | PASS this review: no PCB mutations. Current scene retains original component model references and42×57 mm board summary. Full historical PCB-state equivalence was not independently diffed; fixed topZ0/thickness1.5162 remains the acceptance datum. |
| PCB fasteners/support | FAIL / Error. Both enabled NE/SW retention assets are head-only disks: no shank or engagement. Base has four Ø3.7/Ø2.5 corner rings terminating at−1.5162, without engineered fastener pilots/locators or smooth boss roots. Source also includes a central acoustic annular boss: it must not be overlooked as possible physical contact, but its safe structural landing is unqualified. Therefore the50.3575 mm corner spacing alone is not a complete support-span proof; actual safe support distribution and hardware/head/tool/underside clearance remain NOT VERIFIED. Action: engineer real PCB retention and certify all support landings/span without changing PCB. |
| Insert bores | FAIL / Error. Actual upper pockets are Ø3.63×3.18, equal to the simplified insert OD, with only a lower Ø3.2×1 relief. This is not the selected family's full installation bore. Cylindrical columns lack qualified roots/installation geometry. Action: specify a supported insert/bore/engagement/root interface before heat setting; later torque tests cannot substitute for that design. |
| Independent hatch/bearing | PASS separate-part topology; FAIL / Error bearing. Hatch still begins its pads at13.8 while base columns end13.6:0.2 mm unsupported gap. Action: establish a supported nominal load path and recheck closure; do not rely on screw-induced cover bending. Real battery-disconnect/removal operation NOT VERIFIED. |
| Battery restraint | FAIL / Error. Static pack clearance and vertical extraction assertions concern a42×62×14 block only. Base divider and planning pull-tab are not positive restraint or a swelling-safe holder. Action: complete noncompressive restraint, lead/disconnect/polarity and service-path engineering. |
| Cable panel, lenses and outdoor sealing | FAIL / Error. Panel source is only a42.6×3×13.6 box; lenses are two undersized blocks explicitly deferring bonding/seals. No retained gland/panel interface, continuous compressed enclosure seal, lens retention/seal or acoustic membrane assembly exists in the inspected parts/nodes. Action: complete these physical interfaces and then validate ingress; this is missing engineering, not merely an untested IP claim. |
| Acoustic inlet | PASS source-level central passage intent at(−11.789,2.6135), nominal Ø2 with Ø1.8 test core in the stated window. Complete installed isolation/seal/membrane and exterior-to-microphone route NOT VERIFIED; weather barrier is unfinished engineering. Acoustic response and leakage require tests after that interface exists. |
3D Model
avocaudio-f1-closed-748d9f6d-d075-43f1-a275-dd8c3493a635
avocaudio-f1-open-ef6ee767-34b5-4e84-909c-2638d907b2d9
3D Model
3D Model
Disposition — F1 correction complete; enclosure NOT print-ready
Current separate source assets
Native current views
F1 geometry and verification method
Finite acceptance matrix
Provisional manufacture and assembly notes — NOT a release
Final scene and audit trail
Independent read-only acceptance review — F1, 2026-09-16
Direct evidence and limits
Independent acceptance matrix
Physical-test-only limitations versus unfinished engineering
Exact reviewed references and scope accounting