I confirmed the warning comes from the IC2 VREF pad6 correction ruleset, which forces VREF’s position to X = 1.25 mm, Y = 0.95 mm using !important; it does not itself indicate an electrical error.
In Agent mode, I’ll try removing only the !important flags, verify that VREF stays at the corrected position, and recheck the warning—rather than deleting the pad correction blindly.
Research and calculation completed; battery/charger approval FAILED pending specified evidence. No schematic, component, charger-setting or layout mutations. Read current 109-component schematic and all 112 net memberships, prior power-budget and project-specification files. This file supersedes their numerical budgeting assumptions for this assessment, not their broader release gates. No measured consumption or guaranteed whole-board maximum is available.
Battery: exact listing versus verified hardware
Selected Amazon ASIN B0CR6CH6CF was accessible. It identifies Coonyard, model RC18650-XH254, manufacturer elxjar, nominal 7.4 V, 3000 mAh, 22.2 Wh, 18650 Li-ion, and a two-pack sale. Two-pack means two purchased packs, not proof of cells per pack. Alternate retailer repeats 7.4 V/3000 mAh and built-in overcharge, over-discharge, short-circuit and temperature-protection claims. These are verified listing claims, NOT independently verified protection implementation or thresholds. Its description calls 22.2 Wh a discharge rate: that is dimensionally wrong and provides no current rating.
Table
Item
Confirmed evidence
Approval status
Chemistry / capacity
Seller says 18650 Li-ion, 7.4 V, 3 Ah, 22.2 Wh
Actual cell manufacturer, configuration and tested capacity unknown
Series count
Not explicitly specified; 2S is an engineering hypothesis
Must obtain explicit configuration
Charge voltage/current, temperature
No exact limits recovered
8.4 V compatibility and 0.501 A acceptance unverified
XH2.54/2P stated; Amazon also contained conflicting T-head description
Actual housing, dimensions, keying and polarity unverified
NTC lead
No external probe specification recovered
CN1 probe must be supplied separately and thermally attached
CN2 is JST XH 2.5 mm pitch, rated 3 A with AWG22; matching listed housing is XHP-2. A seller's “XH2.54” label is not mechanical proof of mating. Schematic CN2 pin1 is BAT_PLUS, pin2 GND. Obtain connector face photos/dimensions and measure polarity before plugging in; housing fit does not establish polarity. Do not parallel the two packs.
Inspected power tree
J2 → F2 → CHARGER_VBUS → U11 BQ25886 → SYS/BAT_PLUS. J2 data is charger-only; CC1/2 have separate 5.11k Rd.
J3 → F1 → USB_5V_FUSED → U16 → USB_3V3, supplying U13 only and R1 OE pull. Neither U14 nor U15 is powered by J3.
GND and ISO_GND are separate net memberships. U4 four terminals now connected; older disconnected-U4 descriptions are historical.
CN1 pin1 BAT_TS, pin2 GND. R24 external NTC is excluded from PCB and pick-and-place; do not count it as an installed on-board sensor.
Loads and conditions
Numbers labeled allocation are engineering scenarios, not guaranteed maxima. No firmware radio/CPU duty cycle or maximum bus rate accepted yet.
Table
Rail / actual consumer
Evidence or calculation
Allocation used
MAIN_3V3 U14 ESP32-WROOM-32U
Series-chip RF typical TX 240 mA at 802.11b DSSS1Mbps/+19.5dBm, 190 mA at 11g54Mbps/+16dBm, 180 mA at 11nMCS7/+14dBm; RX95–100mA. These are chip reference modes, not measured complete-module draw. Module external supply minimum capability is 0.5A, NOT maximum consumption.
500mA provisional transient allowance
MAIN_3V3 U8 E22
Manual TX119mA instantaneous and RX6.8mA; TX extraction called this maximum, but exact pulse/test envelope remains unresolved. Retain as stated operating figure, not a board guarantee. Software shutdown sleep2uA typical.
119mA TX /6.8mA RX
MAIN_3V3 U15 CH340C VCC and V3
4mA typical,12mA max at VCC=V3=3.3V electrical-parameter condition; not a whole-temperature universal bound.
12mA
MAIN_3V3 U2 VCC1
Retrieved equal-3.3V table gives8.45mA ICC1/9.20mA ICC2 at I2C400kbps/GPIO50Mbps; actual mixed3.3/5V maximum not established.
15mA provisional
MAIN_3V3 pull networks
R5/R6 4.7k I2C=1.404mA both low; R22/R23 10k status=0.660mA; R13/R15 10k=0.660mA if low; R14/R33 reset/boot=0.660mA if low. R11/R12 GPIO pull-downs add up to0.660mA; Q3/Q4 base paths require output state.
5mA aggregate reserve includes these, not added twice
100mA output rating;5uA headline IQ (not guaranteed maximum).
1mA miscellaneous reserve including U5 IQ
MAIN_5V U4
Only active load is U4. Actual YLPTEC source indexing remained pending after two attempts; distributor says24V42mA/1W/89%,4.5–5.5V and18mA quiescent. These remain unverified engineering values, not approved ratings. Prior file uses a different direct-source revision; reconcile revision before approval.
U13 ICC30uA maximum under specified static rail-input/no-I/O-load conditions. R1=10k draws0.330mA with OE low
0.360mA
J3 U16
100mA output capability; ground2mA typical/5mA max only no-load at VIN≥VOUT+1.5V, so not rigorously guaranteed at4.5V input.
10mA input engineering reserve excluding inrush
BAT_PLUS divider R25/R26
100k+33k gives8.4/133k=63.2uA
explicit battery overhead
SYS U11/bucks housekeeping
U10 IQ22uA typical at ENopen/FB1V, no max; active efficiency already captures most conversion losses. U11 battery IQ12uA typical/20uA max below85C at VBAT9V/noVBUS/ADCdisabled stated conditions, not blanket operating draw.
0.1W additional uncertainty reserve; do not mistake it for measured IQ
Capacitors consume startup/ripple current, not a steady DC load; leakage/ESD leakage and startup surges are not fully established. U9 pin3 is unconnected; there is no separately powered external accessory approved here.
Calculation envelope, not a guaranteed worst case
Conservative scenario inputs: SYS minimum6.0V, nominal7.4V, charge8.4V; bucks85%, U4 70%, charger85%, USB4.5V at U11 AFTER path drop. None of these efficiency/minimum-battery assumptions is a guaranteed pack specification. U11 SYS_MIN6.2V minimum/6.4V typical applies when battery below SYS_MIN and charging disabled with powered regulation, not battery-only minimum.
Equations: switching Iin=Vout×Iout/(Vin×eta); LDO Iin≈Iout+IQ. Total ISO_5V=24.626mA; ISO_RAW=27.726mA≈0.6654W at24V. U4 input=0.6654/(5×0.70)+0.018≈0.2081A MAIN_5V. MAIN_3V3=0.651055A. SYS power=3.3×0.651055/0.85+5×0.2081/0.85+0.1≈3.852W. At6V≈0.642A; at7.4V≈0.521A, plus battery-divider overhead and battery-path losses. This increases prior3.805W estimate by using18mA rather than10mA unverified converter overhead.
A representative active RF scenario replacing ESP32 allowance with240mA reference TX and radio with6.8mA RX gives MAIN_3V3≈278.855mA and SYS≈2.407W, or0.401A at6V/0.325A at7.4V. This combines typical/reference figures with reserves and is NOT typical measured receiver use. Actual ESP32 with Wi-Fi disabled may differ substantially. Radio/CPU duty-cycle and external analog-load data are missing, so no guaranteed peak, average, or sleep total is claimed. Bucks always enabled; isolated converter/LDO/bleed/DAC/CH340 remain powered even if ESP32 sleeps.
Charger settings and simultaneous operation
Current net inspection confirms R18=1.91k from ICHGSET to GND, R19=1.37k from ILIM to GND and VSET explicitly no-connect.
VSET floating selects8.4V. Battery listing did NOT confirm8.4V charge acceptance.
ICHG=RICHGSET/KICHGSET with typical3810Ω/A →1910/3810=0.5013A nominal, about0.167C relative to claimed3Ah; capacity is NOT evidence this charge rate is safe.
IINMAX=KILIM/RILIM, typical1110AΩ →1110/1370=0.8102A nominal. Resistor and regulation tolerances remain to evaluate; this is not USB authorization.
Actual input limit is lower of ILIM and source detection (plus ICO for DCP); unknown5V source/SDP default500mA, CDP1.5A, DCP3A detection values. Rd alone does not authorize1.5/3A; no CC-current reader or PD controller appears in current schematic. Confirm actual adapter and cable; generic computer USB legality/enumeration is not established by automatic detection alone.
At8.4V/0.5013A charge power≈4.211W. Simultaneous provisional-envelope use plus full nominal charging requests(3.852+4.211)/(4.5×0.85)≈2.108A from J2. This is hypothetical demand, NOT actual draw:0.8102A setting permits≈3.099W at4.5V/85%, less than3.852W system scenario. At500mA detection, only≈1.913W. Even2.407W representative scenario leaves little/no charging headroom (about82mA battery charging at8.4V with0.8102A source scenario, ignoring additional losses). Charger reduces charging and can enter battery supplement when system load still overloads input. Receiver use plus USB connection can therefore drain the battery. Separate J3 demand must not be counted against F2/J2.
NTC / thermal / rating margins
R20=5.23k REGN→TS, R21=30.1k TS→GND, external R24/CN1 NTC TS→GND. TS requires NTC divider qualification and charging pauses outside the valid window. Exact probe R25/Beta/tolerance/thermal mounting and seller's charging temperature must be reconciled; no pack protection substitute accepted. With assumed10k at25C: divider ratio (30.1k||10k)/(5.23k+30.1k||10k)=0.589. With CN1 unplugged and no external R24, ratio30.1/(30.1+5.23)=0.852; short gives0. Need threshold comparison and bench open/short tests, not an unsupported claim of fault behavior. No NTC bypass proposed.
Table
Path
Margin assessment
Severity
U10/U7
AP6320x2A continuous output; U10 allocation0.651A uses33%, U7 scenario0.208A uses10% of family nominal capability. Thermal, inductors/ripple/current limit and transients not approved
Warning
U5
24.626mA is25% of100mA rating, but(24−5)×0.024626≈0.468W heat. DGN reference thetaJA66.2C/W →31C rise, NOT actual board temperature proof. Raw converter overshoot, exposed-pad copper and enclosure temperature unverified
Warning
U4
0.665W is67% of distributor1W claim;42−27.726≈14.27mA nominal raw spare, NOT approved external load. Minimum load/regulation/startup and revision conflict pending