Schematic Layout and Connectivity Review


Thought for 1 min 39 sec
Thought for 6 sec
2/2 Verify schematic readability and unchanged electrical connections.

Draft all functional blocks and arrange the full schematic without changing connectivity.

Verify schematic readability and unchanged electrical connections.

Thought for 9 sec
Awaiting 1 task
Thought for 11 sec
"Schematic Verification and Readability" completed.
Thought for 6 mins 32 sec
Thought for 7 sec
Awaiting 1 task
"Schematic Layout and Connectivity Review" completed.
Created a project doc

Schematic drafting status

View Document

Schematic drafting status Scope
Presentation-only drafting requested: readable functional blocks, wires and net labels, with no electrical connection changes or PCB edits.
Completed
  • Arranged all 54 components into card-edge/power entry, USB hub/support, and two SEC1210/SAM blocks. Existing three Functional Group values were preserved; card-edge and hub share a group but form separate visual blocks.
  • Drew local wires and cross-block labels, repositioned support parts, tidied power-entry rows and hub support columns.
  • Fixed stale wire endpoints after J2/J3 mirroring by deleting 64 affected wire segments and allowing correct automatic labelled stubs/ground glyphs. Final check reports zero connected pins without a visible wire, label or ground glyph.
I arranged all 54 components into functional blocks and added wires and net labels, preserving all 52 nets and their electrical connections; the PCB is unchanged. Schematic errors are cleared, but 15 label collisions and 3 wire-crossing warnings remain—details and remaining cleanup are recorded in Schematic drafting status.
Execution stopped because your ACUs ran out.

Waiting for input


Placement Completion — Reviewed Candidate, Not Released
Scope and status (2026-10-06)
This closes the placement work batch, not overall board completion. Routing was explicitly prohibited and remains unattempted. No schematic values, nets, or power architecture were modified in this batch.
WARNING: CUSTOM NON-STANDARD MINI-PCIe PINOUT. DO NOT INSERT INTO A STANDARD MINI-PCIe OR QUECTEL HOST SLOT. Approved host 3.3 V on J1 pins 2/39/41/52 supplies USB2422; host 5 V on repurposed pins 6/28 supplies both SEC1210 VDD5 inputs. SEC1210 VDD33 remains an internal output, capacitor-only. The stale 3.3-V-only knowledge note is superseded by explicit lead approval for this batch.

Table


Assigned itemStatusEvidence / blocker
Reconcile current placement/setupCompleted54 elements, 52 nets; Full-Mini outline and four-layer custom stackup retained
J1 52-contact geometry and face reviewCompletedAll 52 computed pads reread after correction: 0.60 × 2.55 mm, Y=24.075 mm, odd Top/even Bottom, correct existing net IDs
Mounting center/diameter placementCompletedTwo board-level Ø2.6 mm NPTH at (±12.1, −22.575) mm; J1 child mounting placeholders inactive
Local bypass/filter/crystal placementCompletedImproved hub C5–C9/Y1/C10/C11 and SEC C13/C14/C18/C19 clusters; local warnings reduced from nine to four entry-cap warnings
Planar overlap/bounds/keepout reviewCompletedLast placement mutation reported zero overlaps/keepout/bounds violations; final checks did not report these findings
SAM insertion/service and host mechanical fit validationFailed / blockedInsertion direction, service clearance, connector height datum, and host clearances remain unverified; no J2/J3 models
Clean placement signoffFailed / blockedBoard Density Error and C1–C4 loop Warnings persist; mechanical review above incomplete
Documentation/approval checkpointCompletedThis file records exact candidate and release blockers
Routing, final DRC, manufacturing exportUnattemptedOutside authorized batch; no routing performed
Fixed setup and mating geometry
  • Full-Mini board: 30.0 × 50.95 mm, 1.0 mm four-layer stackup. Top Signal / Inner 1 GND / Inner 2 Power / Bottom Signal. Custom stackup profile mfp_8d29705f-05b9-4915-b8b7-45f27c807ebf v1.
  • SDI manufacturing profile mfp_23e942b5-5c91-4fd8-ad4d-d1d2d3e51999 v3, customized. Manufacturer capability target not populated.
  • Board-centered datum; keyed insertion edge at +Y=25.475 mm. Outline X=±15 mm, Y=±25.475 mm. Key X=−4.6 to −3.1 mm, depth 4.0 mm to Y=21.475 mm with rounded bottom.
  • J1 is PCB-only carrier, excluded from BOM and pick-and-place, not a fitted receptacle.
  • Primary PCI-SIG specification Figure 2-5 supersedes secondary KiCad footprint contact length: 2.55±0.05 mm rather than 2.3 mm. Existing common ruleset e47f452e-f40b-4255-8633-7c56a38ed564 now supplies 0.60 × 2.55 mm. Existing per-pin centers retained at Y=24.075 mm, giving outer edge 25.350 mm and 0.125 mm setback, within 0.25 mm MAX.
  • Explicit connectedLayers / Connected-only rules enforce 26 odd contacts Top and 26 even contacts Bottom. Same-face pitch 0.8 mm; opposite-face X stagger 0.4 mm. Every computed pad and existing assigned net was reread after mutation.
  • Mounting separation 24.2 mm; centers 48.05 mm from insertion edge. Real holes are NPTH, not the disabled plated child pads. Fastener/head clearance and any mounting-ground pad requirements are not released.
Mechanical source evidence and caveats
Primary original drawing, printed page 17 / Figure 2-5, was downloaded and visually inspected because datasheet transcription mislabeled vertical key depth as width. Correct key width is 1.50±0.10 mm, depth 4.00±0.10 mm. Do not use the erroneous 4 mm key-width answer. Original drawing preview:

commentFileId-fb80c71040f2cda3d420a09cd2523bb653024df1cd25b4011bbb8fbf8115835f

https://cdn2.flux.ai/flux-comment-files/files/commentFileId-fb80c71040f2cda3d420a09cd2523bb653024df1cd25b4011bbb8fbf8115835f.png?GoogleAccessId=fleet-worker%40graviton-mvp.iam.gserviceaccount.com&Expires=4944875518&Signature=wVkUWw%2FvcHy8z4SYJnURsv7a%2B%2BmtCeBx%2FL8lhrlS7r3PqkHovmPNkSRrqcEcBAFsALYYyjfzGL1C7Qe%2F7Pc7z8IVn%2Flb0S%2FOqxmBty9sXq0DU8jaa%2BffcGU2INAhFmKQcz8MGakN0Y46muLINm8I%2FJhUNqc7PW1ISUOMfYH%2BqIbKHmgIqDM9dzbAiZv5FNsrnEJlG%2F1GmrxuHmHlIMRhEBVMHPTVdiXe32KvSUIv7TL0367gx2C7PhA68pFjjEiCFPvSsUSiL5ui2TtgQnegRFsLWVg1A1%2FITbb7%2FIOrZXHcKTlJh8i4W32dfhEKPVwxLAgi5Y5OhaQjvH3AcE4MWw%3D%3D . Secondary reference: adryzz/M.2-kicad-lib@5bc128e8b7f7, footprints/PCI_Express_Mini_Card.pretty/PCI_Express_Mini_Full_Card.kicad_mod.
Citation-backed mounting/pin-face evidence: . Contact width/pitch/length/inset evidence: . Thickness/component-envelope evidence: . F1/F2 host compatibility: . Keepouts: . SAM nominal body 17.50 ×17.50 ×3.00 mm: .
These evidence references do not establish custom-host fit or SAM insertion/service envelope. The 20.4 mm library connector footprint envelope is not assumed equal to the 17.5 mm body. Connector-envelope gap is only 0.4 mm. SAM nominal 3.00 mm height exceeds both standard card component-envelope figures (2.4/1.35 mm); exact datum and custom-host clearance must be confirmed. F1 Full-Mini-only host use and F2 Half/Full-Mini underside hold-down clearance are distinct; current bottom placement is not certified F2 compliant.
Exact placement snapshot
J2 and J3 are Top, 90°, board-centered at (0,10.175) and (0,−10.625) mm. All other fitted components are Bottom. J1 remains the mixed-face board-only carrier. The table uses scene-tree internal absolute X/Y in millimeters; conversion to board-centered coordinates is Xc=Xraw−1.7, Yc=Yraw+19.385. Do not erroneously apply this internal offset as a physical placement correction. Rotations are degrees as read from the scene tree.

Table


RefXrawYrawRotation
J11.7−19.3850
J21.7−9.21090
J31.7−30.01090
U1−4.7691−20.5428180
U21.7149−19.80780
U3−0.4771−28.1778180
U4−8.0931−14.3778180
U53.6129−25.159890
U63.6129−27.499890
C15.7−1.885270
C25.7−4.385180
C310.2−8.885180
C45.7−6.8850
C5−2.7−15.985270
C6−4.4−24.285180
C7−8.8−18.635180
C8−7−24.335180
C9−1.5−15.68590
C10−7.25−16.96590
C11−3.7−13.485180
C12−12.3441−22.7628270
C131.38−15.585270
C14−1.4−23.985180
C156.3299−19.86430
C1611.39−11.1990
C176.8839−14.61280
C18−0.7−31.785180
C191.25−23.985180
C20−6.5111−31.994890
C2111.39−31.247590
C222.3339−32.77280
R1−3.8921−11.792890
R2−8.8666−20.5428270
R3−8.9666−23.7428270
R4−10.5616−20.5428270
R5−10.6616−23.7428270
R63.7839−15.8948180
R76.3299−21.54680
R8−0.8−33.5850
R95.4954−26.1378270
R10−0.2411−10.7753180
R113.7839−14.19980
R12−4.4−32.085180
R136.1979−28.77380
D1−8.6−27.385270
D25.7−8.8850
D3−7.1051−12.15580
D413.21−9.2190
D5−5.6311−29.25780
D613.21−30.0190
F19.7−1.885180
F29.7−5.585180
FL1−9.7−16.3850
Y1−4.9891−15.867890
Final read-only review
Final get_checks reviewedAt 2026-10-06T08:38:06.552Z, after J1 length correction:
  • Error: 106 airwires. Expected for unrouted design, but real open connections; routing not authorized.
  • Error: 1 Board Density finding. Aggregate report now 1181 mm² /1501 mm² =78.7%. Tool incorrectly attributes all 54 elements to Top although 51 fitted components are Bottom. Keep the Error open and qualify its per-layer calculation; do not claim density is resolved or routing feasibility proven.
  • Warning: 4 Decoupling Loop Area findings, C1/C2/C3/C4. These are rail-entry capacitors positioned near fuse/TVS reservoir cluster; local IC capacitors improved. Warning classification still requires review during power/return-path routing, not suppression.
  • Error: 35 missing MPNs, all generic C1–C22 and R1–R13. Outside placement batch, blocks manufacturing release and exact height verification.
  • Info: J1 Invalid Pads, intentional carrier overrides; noteworthy, not an Error.
  • Requested overlapping-copper, stackup, outside-board, body-overlap, pad-access, oscillator, edge-placement, keepout, and neckdown-escape reviews returned no findings. This is scoped evidence, not a blanket clean-DRC assertion.
No route segments were added. One pre-existing via remains. Planar placement clearance is not a proof of mechanical mating, service access, actual assembled heights, or controlled-impedance routing.
The 2D rendering misleadingly colors all contacts Top and displays inactive child mounting pads as tiny drilled circles. Computed scene-tree geometry with rules included is used as authoritative readback. Internal feedback submissions failed; no ticket was filed.
Approval checkpoint / next batch prerequisites
Before placement finalization or routing authorization, obtain: (1) exact MUP-C746-1 mechanical drawing/model establishing insertion direction, service clearance, and height datum; (2) custom host top/bottom/socket/hold-down clearance and whether F1-only or F2 compatibility is required; (3) mounting screw/head/ground-pad requirements; (4) disposition of density Error and entry-cap Warnings. Manufacturing additionally requires exact generic-part MPNs and full routing/DRC review. Preserve this candidate until those specific blockers are resolved; do not report the overall design complete.
  • Scope and status (2026-10-06)

  • Fixed setup and mating geometry

  • Mechanical source evidence and caveats

  • Exact placement snapshot

  • Final read-only review

  • Approval checkpoint / next batch prerequisites