PFC Switching Power Supply Design
Table
| Hazard | Source | Preliminary Mitigation | Open Item |
|---|---|---|---|
| Electric shock | 120–230 VAC input and ~390 VDC PFC bus | Safety isolation transformer, reinforced spacing, rated optocoupler/isolator, Y-cap limits | Define standard, altitude, pollution degree |
| Fire/overcurrent | Input faults, PFC or DC/DC short | Fuse, current limiting, thermal design, flame-rated parts | Select fuse/coordination method |
| Excess leakage current | Primary-secondary Y capacitors at 400 Hz | Minimize Y-cap value and verify leakage | Define leakage limit and chassis/earth scheme |
| EMI/noncompliance | PFC switching and 400 Hz source interaction | Dedicated EMI filter and layout controls | Define conducted EMI limits |
| Output overvoltage | Feedback failure or controller fault | OVP crowbar/latch-off/supervisor | Choose exact protection implementation |
| Thermal overstress | ~145 W output power, >10 W losses likely | Thermal modeling, copper/heat sinking, airflow | Define ambient/cooling limits |
Table
| Boundary | Primary Side | Secondary Side | Isolation Type | Status |
|---|---|---|---|---|
| Main transformer | PFC/HV bus primary | 12 V/5 V shared secondary | Safety isolation required | Needs transformer design |
| Feedback | Secondary error amplifier | Primary controller | Optocoupler or isolated amplifier | Needs part selection |
| EMI return | Primary/chassis | Secondary return if used | Safety Y capacitor only | Needs leakage analysis |
Status
Applicable Standards To Confirm
Hazard Summary
Isolation Boundary
Safety-Critical Components To Select
Required Documentation Checklist
Open Items