VoltiX Pro 320 Diagnostic Station


I’ll add a Teensy 4.1 socket representation and wire the named control/telemetry nets. First I’ll check whether Pi/Teensy header parts already exist in the schematic/library; if a full Teensy socket part isn’t available, I’ll use a 48-pin dual-row header/socket with explicit net labels for the Teensy functions.
I’m blocked because the project ran out of execution credits during the library search, so I could not add or wire the Teensy socket.
Completed so far:
  • Inspected the schematic: no Raspberry Pi header or Teensy socket currently exists.
  • Searched the library for a Teensy 4.1 / 2x24 / 48-pin female socket: no exact usable part was found.
  • Found a usable Raspberry Pi 5 GPIO header candidate:
    • Pin Socket 02x20 for Rpi 5, 40 terminals, library UID 339d7494-1424-4871-b0a9-f2bc536ebf3e
  • Confirmed the fallback plan: use either two 1x24 female socket strips or a 2x24 48-pin socket if available, then label the Teensy 4.1 functions explicitly.
Still to do once credits are available:
  1. Add the Raspberry Pi 5 40-pin GPIO header.
  2. Add the Teensy 4.1 socket representation, likely as two 1x24 female headers if no exact 2x24 socket exists.
  3. Wire:
    • Teensy pin 1 TX1 -> Pi UART RX
    • Teensy pin 0 RX1 -> Pi UART TX
    • Teensy A0 / pin 14 -> shunt amplifier output net
    • Two Teensy PWM pins -> voltage adjust and current limit control nets
    • Teensy pins 11/12/13 -> SPI MOSI/MISO/SCK expansion nets
    • All Teensy/Pi/analog grounds -> common GND
  4. Run review and fix any ERC issues.
  5. Update the architecture/firmware notes with the final pin mapping.
Find socket headers
Add Pi header
Create pin map
Search 2x24 socket
Inspect existing nets

Waiting for input


Power Budget — Internal Isolated AC-DC Module Architecture
Architecture Boundary
The product uses an internal AC-DC version, but mains is isolated on a separate certified AC-DC module / harness assembly. The main electronics PCB starts at the isolated DC output of that module and remains SELV low-voltage only.
Selected Preliminary DC Bus
  • Nominal isolated DC bus: 36 V DC
  • Reason: provides enough headroom for a 0.2–30 V programmable buck output while keeping bus current lower than a 24 V bus.
  • AC-DC module rating target: >= 360 W, recommended 400 W class for thermal and transient margin.
Output Power Reflection
Assume programmable output stage efficiency of 90–92% at high load.

Table


ConditionCalculation36 V Bus Current
320 W output, 92% efficient320 / (36 x 0.92)9.66 A
320 W output, 90% efficient + 25 W auxiliary budget(320 / 0.90 + 25) / 3610.57 A
Preliminary Rail Budget

Table


RailLoadsTypical / Design BudgetNotes
36 V DC busProgrammable output stage9.7–10.6 ASize connector, fuse, switch/FETs, copper for >= 12 A continuous minimum; 15 A preferred margin.
12 V auxFans, relays, gate drivers1.0–1.5 A provisionalExact fan and relay selection TBD.
5 V auxTouchscreen, USB peripherals/modules2.0–3.0 A provisionalMust account for USB/protocol test port power separately if high-current charging is implemented.
3.3 V logicMCU, ADC, sensors, level shifters0.5–1.0 A provisionalDepends on controller and comms ICs.
Power-Path Sizing Rules
  • DC input connector from the AC-DC module to main PCB: >= 15 A per power contact or multiple contacts paralleled with derating.
  • Main DC input fuse/eFuse path: >= 12 A continuous, preferably 15 A design margin.
  • Programmable output current path: 10 A continuous, with low-ohmic current sense and Kelvin routing.
  • 36 V bus capacitors: voltage rating >= 50 V, preferably 63 V for margin.
  • 12 V / 5 V / 3.3 V auxiliary regulators should be switching regulators, not LDOs, because the input is 36 V.
Safety / Isolation Notes
  • Do not place live/neutral mains nets on the main PCB.
  • The mains module/harness must handle fuse, switch, EMI filtering, earth, strain relief, and safety spacing.
  • Protective earth should bond to chassis/enclosure per safety requirements; SELV 0 V/chassis bonding strategy is a later EMI/safety decision.
Open Items
  • Exact certified AC-DC module MPN and mechanical footprint.
  • Whether the programmable output is a fully custom synchronous buck or a prebuilt programmable DC-DC module.
  • Touchscreen/controller platform choice.
  • Exact expansion-module power limits.
  • Architecture Boundary

  • Selected Preliminary DC Bus

  • Output Power Reflection

  • Preliminary Rail Budget

  • Power-Path Sizing Rules

  • Safety / Isolation Notes

  • Open Items