| 구분 | Designator | 부품명 | MPN | 제조사 | 수량 | 용도 |
|---|---|---|---|---|---|---|
| Power MUX IC | U3 | TPS2121RUXR | TPS2121RUXR | Texas Instruments / TI | 1 | POWER1/POWER2 5V 입력 자동 선택용 power mux |
| CAN Transceiver IC | U1, U2 | TJA1051TK_3,118 | TJA1051TK/3,118 | NXP | 2 | CAN1/CAN2 MCU-side TX/RX ↔ CANH/CANL 변환 |
| MOSFET | Q1 | AO3400 | AO3400 | YFW | 1 | Buzzer 구동용 N-channel MOSFET |
| USB ESD/TVS Array | D1 | USBLC6-2SC6 | USBLC6-2SC6 | STMicroelectronics | 1 | USB D+/D− ESD 보호 |
| USB ESD/TVS Array | D4 | USBLC6-4SC6 | USBLC6-4SC6 | Texas Instruments Inc. / ST 계열 데이터시트 사용 | 1 | USB/IO ESD 보호 |
| CAN ESD Protection | D2, D3 | PESD2CAN,215 | PESD2CAN,215 | Nexperia | 2 | CANH/CANL ESD 보호 |
| Power TVS | D8, D9 | SMAJ5.0A | SMAJ5.0A | SHIKUES | 2 | POWER1/POWER2 입력 TVS 보호 |
| Signal / Flyback Diode | D5 | 1N4148WS-7-F | 1N4148WS-7-F | Diodes Incorporated | 1 | Buzzer/신호 보호용 다이오드 |
flux
design_rule_check_overlapping_copperU1 / internal element UID d07ee657-77c1-4c1e-b1f8-e1a179c8f4faU2 / internal element UID e3c02cf9-7cac-429c-9723-61113e4c6985Table
| Issue group | Affected component / footprint | Layer | Overlap type | Likely cause | Recommended fix |
|---|---|---|---|---|---|
| 1 | U1, TJA1051TK/3 CAN transceiver, footprint for TJA1051TK_3,118, located near (-40 mm, 35 mm) | Top copper / component side | Internal footprint mount pads overlap exposed pad EPAD | Footprint geometry issue, not placement. The DRC pairs each of four unnamed defaultFootprint.mounts.* pads against U1:EPAD. | Replace or edit the TJA1051 footprint so mechanical/mount pads do not create separate overlapping copper on top of EPAD. Preferred: use a clean HVSON/VSON-8 CAN transceiver footprint where the exposed thermal pad is one GND copper pad and package/mount primitives are non-copper or excluded from DRC. If those four mount pads are intentional same-net copper, merge/assign them to the exposed GND pad geometry rather than leaving them as separate overlapping pads. |
| 2 | U2, TJA1051TK/3 CAN transceiver, footprint for TJA1051TK_3,118, located near (-40 mm, 24 mm) | Top copper / component side | Internal footprint mount pads overlap exposed pad EPAD | Same footprint geometry issue as U1; same part and footprint reused. Not caused by U1/U2 proximity. | Apply the same footprint correction/replacement to U2. Do not move U2 to fix this; placement is not the root cause. |
U1 internal UID d07ee657...defaultFootprint.mounts.06303... overlapping EPADdefaultFootprint.mounts.453f... overlapping EPADdefaultFootprint.mounts.60ba... overlapping EPADdefaultFootprint.mounts.eb9c... overlapping EPADU2 internal UID e3c02cf9...defaultFootprint.mounts.* patterns overlapping EPADd07ee657-77c1-4c1e-b1f8-e1a179c8f4fa -> U1, TJA1051TK/3 CAN transceivere3c02cf9-7cac-429c-9723-61113e4c6985 -> U2, TJA1051TK/3 CAN transceiverU1: center approximately (-40 mm, 35 mm), top layerU2: center approximately (-40 mm, 24 mm), top layerEPAD and GND are on the GND net, so this is most likely same-net/footprint-internal copper overlap. The DRC still flags it because the footprint contains separate overlapping copper primitives.U1 and U2 overlapping each other; they are separated by about 11 mm center-to-center.TJA1051TK_3,118 has copper mount primitives overlapping the exposed pad.TJA1051TK_3,118 footprint used by U1 and U2 with a clean manufacturer/library footprint for the correct TJA1051TK package.EPAD copper pad instead of being separate overlapping pad objects.design_rule_check_overlapping_copper after the footprint correction.U1 and U2 footprint-overlap errors are resolved or explicitly waived as intentional same-net footprint geometry.Current DRC Summary
Issue Table
Evidence
DRC item pattern
Component mapping
Root Cause Classification
Exact Fix Recommendation Before Routing
Routing Gate