15 Volt Power Delivery Setup

Connect the resistors R1, R2, R3 and R4 to the right components
411 days

0:56

The intended net connections for the resistor network are as follows:

Table


ResistorConnected FromConnected ToValueFunction
R1USB Type‑C CC1 (Net4)VBUS (Net1)56 kΩPull‑up for CC1
R2USB Type‑C CC1 (Net4)GND (Net2)22 kΩPull‑down for CC1
R3USB Type‑C CC2 (Net5)VBUS (Net1)56 kΩPull‑up for CC2
R4USB Type‑C CC2 (Net5)GND (Net2)22 kΩPull‑down for CC2
These connections ensure that the CC1 line is pulled up to VBUS through [R1] and pulled down to GND through [R2], while the CC2 line is pulled up to VBUS through [R3] and pulled down to GND through [R4], which is the correct setup for triggering a 15‑volt contract with USB Power Delivery.
List missing components for IC1
Component Specifications
Net names clarification
411 days