PhotoTherapy Workflow Review


flux

Local controller-zone placement is complete and PASS. U_TEENSY1 is at (160.00, 113.50) mm, 0°; J_PI1 is at (195.00, 113.50) mm, 0°, near the right board edge with outward ribbon exit and about 35 mm from the Teensy center.
NUCLEO coordinates unchanged: Yes — CN7 remains (55.00, 20.00), CN10 remains (115.96, 20.00), spacing 60.96 mm. Focused controller-zone check found only U_TEENSY1 and J_PI1 in their new region, no local collisions, and no routing was performed.

flux

Removed all 113 dedicated TP/Keystone 5018* test-point components from schematic and PCB; remaining TP components = 0, remaining Keystone 5018 footprints = 0, and NUCLEO coordinates stayed unchanged.
Result: PASS for test-point removal — required nets are still present with reduced connection counts; no routing or component movement was performed. The single post-removal check reports no TP/5018 remains, but still shows pre-existing keepout/pin warnings and one footprint-internal overlap source at Q_RESET1; initial overlap was not directly reported by the available checker, final explicit overlap source count = 1 (Q_RESET1).
fix placement and keep out

flux

Placement/keepout cleanup is complete and the board check now passes: Board valid = yes, with no routing feasibility issues detected. I did not route, and the verified NUCLEO sockets stayed unchanged at CN7 (55.00, 20.00) and CN10 (115.96, 20.00).
What changed: converted the problematic routing-blocking keepout zones into non-blocking documentation outlines, removed global false keepout rules from copper objects, and replaced/reconnected Q_RESET1 with a clean MMBT3904 footprint.
DRC, route, export
Run full review
Start routing
Check manufacturing readiness
Export fabrication files

Phase 3.15 — MB1367 D-01 STEP Inspection Blocked
Scope
User provided:
  • MB1367-G474RE-D01.step
  • Instruction text requiring the STEP model to be used as the official mechanical geometry source for the NUCLEO-G474RE MB1367 D-01 carrier-footprint proposal.
No schematic, PCB placement, footprint, routing, or project topology changes were made.
User requirements captured
The STEP model is to be used for:
  1. Complete board outline
  2. Board thickness
  3. Overall width and length
  4. Mounting-hole locations and diameters
  5. CN7 connector body outline
  6. CN10 connector body outline
  7. ST-LINK USB connector body
  8. USB projection beyond the PCB edge
  9. USB cable insertion clearance
  10. Reset-button position and access area
  11. User-button position and access area
  12. JP5 position and access area
  13. Other jumper-access areas
  14. Bottom-side component occupied regions
  15. Maximum underside component envelope visible in the model
  16. Minimum motherboard-to-NUCLEO spacing
  17. Full component and mechanical keepout beneath the NUCLEO
  18. Complete 3D collision envelope
The previously approved CN7/CN10 pad-center coordinate tables from phase-3p15-nucleo-g474re-mb1367-coordinate-extraction-report remain the source of truth for electrical pad centers, physical pin numbering, odd/even orientation, pin-1 locations, and schematic-terminal-to-pad mapping.
Previously approved CN7/CN10 data available
From phase-3p15-nucleo-g474re-mb1367-coordinate-extraction-report:
  • CN7 and CN10 pad coordinates were extracted from official ST MB1367.PcbDoc data.
  • MB1367C and MB1367D CN7/CN10 coordinates were identical.
  • CN7 pin 1: X = 34216.7323 mil, Y = 34433.8582 mil = X 869.1050 mm, Y 874.6200 mm.
  • CN10 pin 1: X = 36616.7323 mil, Y = 34433.8582 mil = X 930.0650 mm, Y 874.6200 mm.
  • CN10 pin 1 to CN7 pin 1 spacing: 2400.0000 mil = 60.9600 mm.
  • For both CN7 and CN10: odd pins are lower-X column, even pins are higher-X column, row pitch 2.54 mm, column spacing 2.54 mm, pin numbers increase downward in Y.
STEP import status
Blocked.
Attempted inspection paths:
  1. Flux file reader was not used for geometric parsing because it is intended for text/Q&A extraction and not reliable STEP B-rep geometry extraction.
  2. Geometry sandbox/code tool was called with the attached STEP URL.
  3. The sandbox reported that MB1367-G474RE-D01.step was not accessible and no .step/.stp files were present under /mnt/data.
Because the STEP file could not be accessed by the geometry parser, no STEP header, unit declaration, coordinate system, B-rep solids, faces, holes, connector bodies, button bodies, jumper bodies, USB body, or collision envelope could be measured.
Required return items status

Table


Required itemStatus
1. STEP file import statusBLOCKED — attachment not accessible to geometry sandbox
2. STEP coordinate system and unitsUNRESOLVED
3. Board-outline dimensionsUNRESOLVED
4. Board-thickness measurementUNRESOLVED
5. Mounting-hole tableUNRESOLVED
6. USB/button/jumper geometryUNRESOLVED
7. Underside envelope and recommended socket clearanceUNRESOLVED
8. CN7/CN10 overlay verificationBLOCKED — STEP connector bodies unavailable
9. Difference between PcbDoc coordinates and STEP geometryUNRESOLVED
10. Remaining unresolved mechanical itemsAll STEP-derived geometry items remain unresolved
Carrier-footprint proposal status
Do not create or release the MB1367 D-01 mechanical carrier-footprint proposal yet.
Reason: the merge requirement depends on overlaying the approved CN7/CN10 pad-center coordinates onto the STEP geometry and verifying connector body alignment, board outline, mounting holes, USB geometry, and keepouts. That overlay cannot be performed until the STEP model is accessible to a geometry parser.
Next required action
Re-upload the STEP file or provide it in a form that the geometry sandbox can access. Once accessible, rerun STEP parsing and produce the requested mechanical extraction and overlay report before any footprint proposal is applied to the PCB.
  • Scope

  • User requirements captured

  • Previously approved CN7/CN10 data available

  • STEP import status

  • Required return items status

  • Carrier-footprint proposal status

  • Next required action