PhotoTherapy Workflow Review


flux

Local controller-zone placement is complete and PASS. U_TEENSY1 is at (160.00, 113.50) mm, 0°; J_PI1 is at (195.00, 113.50) mm, 0°, near the right board edge with outward ribbon exit and about 35 mm from the Teensy center.
NUCLEO coordinates unchanged: Yes — CN7 remains (55.00, 20.00), CN10 remains (115.96, 20.00), spacing 60.96 mm. Focused controller-zone check found only U_TEENSY1 and J_PI1 in their new region, no local collisions, and no routing was performed.

flux

Removed all 113 dedicated TP/Keystone 5018* test-point components from schematic and PCB; remaining TP components = 0, remaining Keystone 5018 footprints = 0, and NUCLEO coordinates stayed unchanged.
Result: PASS for test-point removal — required nets are still present with reduced connection counts; no routing or component movement was performed. The single post-removal check reports no TP/5018 remains, but still shows pre-existing keepout/pin warnings and one footprint-internal overlap source at Q_RESET1; initial overlap was not directly reported by the available checker, final explicit overlap source count = 1 (Q_RESET1).
fix placement and keep out

flux

Placement/keepout cleanup is complete and the board check now passes: Board valid = yes, with no routing feasibility issues detected. I did not route, and the verified NUCLEO sockets stayed unchanged at CN7 (55.00, 20.00) and CN10 (115.96, 20.00).
What changed: converted the problematic routing-blocking keepout zones into non-blocking documentation outlines, removed global false keepout rules from copper objects, and replaced/reconnected Q_RESET1 with a clean MMBT3904 footprint.
DRC, route, export
Run full review
Start routing
Check manufacturing readiness
Export fabrication files

Schematic of PhotoTherapy16_v2.0
U_REG_ANALOG
U_REG_LOGIC
C_REG_ANALOG_IN
Capacitance
1uF
C_REG_ANALOG_OUT
Capacitance
1uF
C_REG_LOGIC_OUT
Capacitance
1uF
C_REG_LOGIC_IN
Capacitance
1uF

PhotoTherapy16_v2.0

PhotoTherapy16_v2.0 thumbnail