Hydro Sensor Build Assistance


flux

  • Added 1x SRDA3.3-6.TBT as D1

Summarizing remaining design issues and to-dos...

0:38

Started: 13.3. Summarize any remaining issues and share a to-do list with the user.

flux

Work completed:
  • System architecture defined and saved
  • ESP32, USB-C panel connector, BNC connector, sensor connectors added
  • 3.3 V regulator and decoupling capacitors placed
  • Pull-ups (4.7 kΩ), RC filters, ESD diodes added and nets connected
  • ERC-driven reviews done, passive/component footprints set, MPN replacements applied
Remaining tasks:
  • Define cable-gland keep-out zones, hydrophobic vent placement, and mounting-hole locations in PCB layout
  • Classify nets and assign trace widths, configure copper pours and power planes
  • Place components and route nets on PCB
  • Perform PCB DRC/ERC in layout and resolve any issues
  • Develop firmware scaffold and bring-up checklist (outside Flux scope)
Success criteria status:
  • Schematic is complete with pull-ups, RC filters, decoupling caps, ESD protection: ✅
  • PCB mechanical allowances (holes, glands, vent) still need layout placement: ❌
  • Layout separation of analog/RF signals pending routing: ❌
  • Firmware scaffold and bring-up documentation pending: ❌
  • ERC/DRC is clean in schematic; layout checks pending: ❌
Next step: Prepare the PCB layout mechanical provisioning step—define mounting holes, cable-gland keep-outs, and vent footprint per the IP65 enclosure in the “Prepare PCB Layout” phase of the workflow.

J4
J3
R6
Resistance
500 Ω
C4
C3
Capacitance
Capacitance
C1
Capacitance
Capacitance
C5
Capacitance
Capacitance
R1
Resistance
500 Ω
C4
Capacitance
Capacitance
R4
Resistance
500 Ω
C1
R2
Resistance
500 Ω
C3
R5
Resistance
500 Ω
R3
Resistance
500 Ω
C2
Capacitance
Capacitance
R3
Resistance
1kΩ
SW1
R2
Resistance
4.7kΩ
R1
Resistance
4.7kΩ
R6
Resistance
4.7kΩ
R5
Resistance
4.7kΩ
R4
Resistance
1kΩ
D1
J6
J5
J2
D1
U2
J1
C2
Capacitance
10µF

Hiro PH Display 1.0