Electrical Resume Handoff
Status: incomplete and unsafe to energize. Resume interrupted by exhausted ACUs. No drawing/layout performed. Read Project Specification and existing Capture Status and Resume Notes too.
Actual changes this resume
- K1–K4 replaced with sealed Omron G5LE-14 5VDC, tool verified five nets preserved each. Datasheet mapping confirmed: 1 COM, 2/5 coil, 3 NO, 4 NC. Prior suspected NO/NC inversion was not real. Published inductive ratings are at 120/250VAC; do not claim a specifically tested 24VAC rating or actual-load compatibility.
- Added PW1 Mornsun URB4805LD-30WR3 (18–75V input, 80V max, 5V/6A) but NOT wired. Old U1 55V module remains. Source https://www.mornsun-power.com/public/uploads/pdf/URB_LD-30WR3.pdf . Pins reported 1 Ctrl, 2 GND, 3 Vin, 4 +Vo, 5 0V, 6 Trim. Independently verify before wiring. Open Ctrl enables. Reported body 50.8x25.4mm, pin grid 45.72x20.32mm; full drawing must govern footprint.
- Added C3 Samyoung NXA 470uF/100V C165656; NOT wired, C1 remains. Ripple rating and polarity not verified.
- Added BOM-only fuse F3, 0218001.MXEP library instance with MPN 0218001.MXP, excluded from PCB. Reconcile suffix before purchasing.
- Added unwired Q5/Q6 2N7000TA, R4/R5 4.7k for proposed I2C isolation; R6–R9 43k for voltage-mode attenuation; D7–D14 1N4148TA clamp pairs; D15/D16 SB160, D17 1N5226B, D18 1N4007 for proposed clamp/sensor protection.
- No ERC rerun. Reported new checks: 48 floating pins and 8 unspecified-pin-type warnings in addition to earlier four errors/six warnings; not a current verified aggregate.
Critical newly discovered defect
U2 D36V28F3 requires minimum 5.3V input per Pololu page, but current design feeds it from 5V. Resolve before energizing: choose a verified 3.3V module that regulates from 5V at >=600mA, or redesign feed with ratings and protection checked. EN reportedly has 100k pull-up to VIN; PG open drain. Current/header geometry still unverified; old 3.6A metadata untrusted.
Proposed changes NOT implemented; require validation
- PW1 Vin to VRAW_DC, GND/0V to GND, +Vo to 5V; remove old U1 after verification. Proposed D1 P6KE56A has 77V nominal published clamp versus 80V converter absolute max: insufficient evidence for robust surge protection; include clamp tolerance, dynamic overshoot, pulse energy and fuse/MOV coordination. Do NOT declare protected from 3V arithmetic headroom.
- Proposed ADC topology per channel: input through 22k to ANn_SEL; selectable 43k-to-GND for 0–3.3V or 6.2k-to-GND for 0–10V; 10k series to GPIO; NTC mode no selector shunt. Nominal max ADC 2.183V/2.199V. Verify exact component designators and topology before mutation. Existing divider remains wrong and loads NTC.
- Proposed ANn_SEL clamps to VCLAMP/GND; VCLAMP biased AUX_3V3 through SB160 and shunted by 3.3V zener. NOT validated: report estimates up to 0.4mA into unpowered MCU with no published injection allowance. Cannot claim 24VAC fault survival. Zener low-current tolerance, diode Vf, MCU powered/unpowered limits and negative fault must be validated. 1N4148 clamps alone not sufficient.
- Proposed AUX_3V3 -> D16 -> SENS_INT -> F2 -> SENSOR_3V3, D18 GND anode to SENS_INT cathode. Positive 24VAC on sensor supply is blocked from AUX, but exposed sensor remains exposed and PTC/diode protection on negative half-cycle requires current/energy/inrush checks. Diode drop also changes sensor supply accuracy.
- Proposed I2C 2N7000 level shifter: MCU-side source and pull-ups to DEV_3V3, AUX-side drain, gate DEV_3V3. Check both domains' power sequencing, body diode direction, USB GPIO19 startup pull-up and device thresholds before claim of isolation.
- Proposed R20–R23 pull-down reduction 10k->4.7k for GPIO6 reset pull-up. Validate worst-case transistor cutoff.
Remaining work/checkpoint
Complete safe electrical corrections, then rerun ERC and bounded checks. All new parts mostly floating; no clean schematic checkpoint. No PCB placement/routing. Exact ESP32 header row spacing and OLED module geometry remain open. Source R/C MPNs, polarized bulk ripple rating, transformer rating/inrush and real loads. Relay snubber leaks ~0.9mA at 60Hz; load suitability unknown.
User-facing decisions and defaults
Direction already stated to user: retain >=60V converter, preserve 0–3.3V input with attenuation, passive/separately isolated sensors only, no common tied to 24VAC legs. Safe component substitutions authorized; no need to ask permission again for ordinary relay/module substitutions, but record them. URB4805LD-30WR3 and G5LE-14 are candidate/implemented substitutions respectively. Proposed analog protection is NOT yet acceptable; user acceptance cannot replace engineering proof. Ask for actual per-channel loads and sensor models; default design envelope isolated 24VAC accessories <=2A/channel, with independent life-support safeguards. Confirm exact module/board variant if authoritative geometry unavailable.
Resumption
Existing capture work context is executor wt; independent prior reviewer yp already performed one incomplete review. Reuse capture context for focused fixes; do not restart broad research or claim reviewer validation. Last active lifecycle result was interrupted; later capture report says partial/completed due ACUs. Recover status before dispatch. Next priority: resolve U2 min input, finish main power replacement safely, solve validated unpowered ADC protection, then finish connectivity and checks. Never energize current partial circuit.