Schematic Layout Drafting


Draw schematic

I’ll arrange the existing circuit into readable functional blocks, draw local wires, and use net labels between blocks. I’ll check that every electrical connection stays unchanged.
Finished execution
"ESP32 Aquarium Schematic Drafting" completed.
Created a project doc

Schematic drafting handoff

View Document

Schematic drafting handoff
User request: arrange readable functional blocks, draw wires and labels, and do not change electrical connections.
Completed presentation pass
Drafting run kw reports four successful presentation-only mutations: packed 13 existing functional groups covering 95 baseline parts; drew 51 local same-net wires (10 long wires converted to labels); laid out input and buck power blocks above, analog channels left, MCU/OLED center, four relay blocks right; aligned rails and placed labels. Tidy made no changes.
Concurrent changes and verification limits
Run reports 23 components appeared concurrently (D7–D18, R4–R9, Q5/Q6, PW1, C3, F3), raising count to 118. Relay K1–K4 part names changed from G5LE-1-E DC5 to G5LE-14 5VDC. These changes were not made by the dr...
I completed a first drafting pass: arranged the original 95 components into 13 functional blocks, drew local wires, and placed net labels and power/ground symbols.
The schematic is not finished. Collisions and label cleanup remain. During drafting, concurrent edits added 23 parts and changed the relay parts, so I could not fully verify that pin-by-pin connectivity stayed unchanged. My drafting edits changed presentation only.
I saved the progress and remaining checks in the Schematic drafting handoff.
Execution stopped because your ACUs ran out.

Waiting for input


Electrical Resume Handoff
Status: incomplete and unsafe to energize. Resume interrupted by exhausted ACUs. No drawing/layout performed. Read Project Specification and existing Capture Status and Resume Notes too.
Actual changes this resume
  • K1–K4 replaced with sealed Omron G5LE-14 5VDC, tool verified five nets preserved each. Datasheet mapping confirmed: 1 COM, 2/5 coil, 3 NO, 4 NC. Prior suspected NO/NC inversion was not real. Published inductive ratings are at 120/250VAC; do not claim a specifically tested 24VAC rating or actual-load compatibility.
  • Added PW1 Mornsun URB4805LD-30WR3 (18–75V input, 80V max, 5V/6A) but NOT wired. Old U1 55V module remains. Source https://www.mornsun-power.com/public/uploads/pdf/URB_LD-30WR3.pdf . Pins reported 1 Ctrl, 2 GND, 3 Vin, 4 +Vo, 5 0V, 6 Trim. Independently verify before wiring. Open Ctrl enables. Reported body 50.8x25.4mm, pin grid 45.72x20.32mm; full drawing must govern footprint.
  • Added C3 Samyoung NXA 470uF/100V C165656; NOT wired, C1 remains. Ripple rating and polarity not verified.
  • Added BOM-only fuse F3, 0218001.MXEP library instance with MPN 0218001.MXP, excluded from PCB. Reconcile suffix before purchasing.
  • Added unwired Q5/Q6 2N7000TA, R4/R5 4.7k for proposed I2C isolation; R6–R9 43k for voltage-mode attenuation; D7–D14 1N4148TA clamp pairs; D15/D16 SB160, D17 1N5226B, D18 1N4007 for proposed clamp/sensor protection.
  • No ERC rerun. Reported new checks: 48 floating pins and 8 unspecified-pin-type warnings in addition to earlier four errors/six warnings; not a current verified aggregate.
Critical newly discovered defect
U2 D36V28F3 requires minimum 5.3V input per Pololu page, but current design feeds it from 5V. Resolve before energizing: choose a verified 3.3V module that regulates from 5V at >=600mA, or redesign feed with ratings and protection checked. EN reportedly has 100k pull-up to VIN; PG open drain. Current/header geometry still unverified; old 3.6A metadata untrusted.
Proposed changes NOT implemented; require validation
  • PW1 Vin to VRAW_DC, GND/0V to GND, +Vo to 5V; remove old U1 after verification. Proposed D1 P6KE56A has 77V nominal published clamp versus 80V converter absolute max: insufficient evidence for robust surge protection; include clamp tolerance, dynamic overshoot, pulse energy and fuse/MOV coordination. Do NOT declare protected from 3V arithmetic headroom.
  • Proposed ADC topology per channel: input through 22k to ANn_SEL; selectable 43k-to-GND for 0–3.3V or 6.2k-to-GND for 0–10V; 10k series to GPIO; NTC mode no selector shunt. Nominal max ADC 2.183V/2.199V. Verify exact component designators and topology before mutation. Existing divider remains wrong and loads NTC.
  • Proposed ANn_SEL clamps to VCLAMP/GND; VCLAMP biased AUX_3V3 through SB160 and shunted by 3.3V zener. NOT validated: report estimates up to 0.4mA into unpowered MCU with no published injection allowance. Cannot claim 24VAC fault survival. Zener low-current tolerance, diode Vf, MCU powered/unpowered limits and negative fault must be validated. 1N4148 clamps alone not sufficient.
  • Proposed AUX_3V3 -> D16 -> SENS_INT -> F2 -> SENSOR_3V3, D18 GND anode to SENS_INT cathode. Positive 24VAC on sensor supply is blocked from AUX, but exposed sensor remains exposed and PTC/diode protection on negative half-cycle requires current/energy/inrush checks. Diode drop also changes sensor supply accuracy.
  • Proposed I2C 2N7000 level shifter: MCU-side source and pull-ups to DEV_3V3, AUX-side drain, gate DEV_3V3. Check both domains' power sequencing, body diode direction, USB GPIO19 startup pull-up and device thresholds before claim of isolation.
  • Proposed R20–R23 pull-down reduction 10k->4.7k for GPIO6 reset pull-up. Validate worst-case transistor cutoff.
Remaining work/checkpoint
Complete safe electrical corrections, then rerun ERC and bounded checks. All new parts mostly floating; no clean schematic checkpoint. No PCB placement/routing. Exact ESP32 header row spacing and OLED module geometry remain open. Source R/C MPNs, polarized bulk ripple rating, transformer rating/inrush and real loads. Relay snubber leaks ~0.9mA at 60Hz; load suitability unknown.
User-facing decisions and defaults
Direction already stated to user: retain >=60V converter, preserve 0–3.3V input with attenuation, passive/separately isolated sensors only, no common tied to 24VAC legs. Safe component substitutions authorized; no need to ask permission again for ordinary relay/module substitutions, but record them. URB4805LD-30WR3 and G5LE-14 are candidate/implemented substitutions respectively. Proposed analog protection is NOT yet acceptable; user acceptance cannot replace engineering proof. Ask for actual per-channel loads and sensor models; default design envelope isolated 24VAC accessories <=2A/channel, with independent life-support safeguards. Confirm exact module/board variant if authoritative geometry unavailable.
Resumption
Existing capture work context is executor wt; independent prior reviewer yp already performed one incomplete review. Reuse capture context for focused fixes; do not restart broad research or claim reviewer validation. Last active lifecycle result was interrupted; later capture report says partial/completed due ACUs. Recover status before dispatch. Next priority: resolve U2 min input, finish main power replacement safely, solve validated unpowered ADC protection, then finish connectivity and checks. Never energize current partial circuit.
  • Actual changes this resume

  • Critical newly discovered defect

  • Proposed changes NOT implemented; require validation

  • Remaining work/checkpoint

  • User-facing decisions and defaults