Part Information Review and Datasheet Update


Yes — the incomplete connections are on the PCB layout, not the schematic.
The review shows:
  • Airwires: 7 errors = missing routed traces between pads
  • Floating Pin: clean
  • Single Pin Nets: clean
  • Undriven Nets: clean
That matches Flux’s review definition: an airwire means a net is connected logically but not yet routed as copper on the board
What is already connected in the schematic:
  • GND: J1 pin 2, J3 pin 2, Q1 source, R2 pin 2
  • +24V: J1 pin 1, J2 pin 1, D1 cathode
  • SOL_LOW: J2 pin 2, Q1 drain, D1 anode
  • GPIO_IN: J3 pin 1 to R1
  • GATE: R1, R2, and Q1 gate
So the issue is:
  • the board still needs copper traces between those pads
  • not that J1, J3, or R2 are electrically undefined
Also, when reporting project state, the right approach is to describe what is actually present and separate concerns like unrouted connections from the functional schematic state
What still needs routing

Table


NetPads needing copper connection
GNDJ1, J3, Q1, R2
+24VJ1, J2, D1
SOL_LOWJ2, Q1, D1
GPIO_IN / GATEJ3, R1, R2, Q1
If you want, I can next give you a pad-by-pad manual routing order for J1, J2, J3, D1, Q1, R1, and R2 so you can clear the airwires quickly.
Give routing order
Check all DRC
Show board summary

Waiting for input


Schematic is Auto-placed

The schematic has been arranged automatically. Flux can redraw it to be more readable, with components placed in related groups and wires drawn more legibly. This takes about 10-60 mins.

Name
Section
Pin Group
Orientation
Order
Sub-symbol

24V Solenoid Driver