Left Daughterboard Schematic


The schematic is now populated. I’m doing one bounded connectivity review, focused on confirming the completed sensor/connector sections and identifying exactly what remains open in the CTA block.
Created a project doc

Schematic Review and BOM

View Document

Schematic Review and BOM Current Status
The schematic is populated with 28 components and 12 named nets. The Brain connector, power decoupling, TSIC306 section, GY-906 section, ground-domain separation, and all required test points are electrically connected. The FS7 CTA active network is intentionally not wired because an authoritative manufacturer topology could not be reliably extracted; guessing this feedback circuit would violate the project requirements.
Verified Connectivity
  • Molex J1 pins 3-10 map to the exact required nets.
  • J1 pins 1 (+12V_SYS) and 2 (PWR_GND) are marked intentional no-connect.
  • AGND and DGND are separate nets.
  • TSIC306 U2: pin 1 -> DGND, pin 2 -> TSIC_DATA, pin 3 -> +5V_LOGIC; C3 is fitted.
The schematic has been populated with 28 components and 12 named nets. Completed sections include:
  • Molex Micro-Fit connector and required pin mapping
  • Intentional NCs on pins 1 and 2
  • Separate AGND and DGND
  • TSIC306 wiring and decoupling
  • GY-906 wiring and decoupling
  • Connector-entry bulk capacitors
  • All required test points
  • FS7 CTA components with specified values and ratings
The FS7 CTA components remain unwired because the authoritative CTA circuit figure could not be reliably extracted. I did not invent the feedback topology. Consequently, 22 ERC floating-pin errors remain, all confined to U1, Q1, and R1–R7 in that block.
Documentation created:
Open item: Supply the existing FS7 CTA schematic or a legible IST application-note figure showing every U1/Q1/R1–R7/FS7 connection. Then only CTA wiring and one final ERC pass remain. No PCB layout was started.
Execution stopped because your ACUs ran out.

Waiting for input


Schematic Review and BOM
Current Status
The schematic is populated with 28 components and 12 named nets. The Brain connector, power decoupling, TSIC306 section, GY-906 section, ground-domain separation, and all required test points are electrically connected. The FS7 CTA active network is intentionally not wired because an authoritative manufacturer topology could not be reliably extracted; guessing this feedback circuit would violate the project requirements.
Verified Connectivity
  • Molex J1 pins 3-10 map to the exact required nets.
  • J1 pins 1 (+12V_SYS) and 2 (PWR_GND) are marked intentional no-connect.
  • AGND and DGND are separate nets.
  • TSIC306 U2: pin 1 -> DGND, pin 2 -> TSIC_DATA, pin 3 -> +5V_LOGIC; C3 is fitted.
  • GY-906 MOD1: VCC -> +5V_LOGIC, GND -> DGND, SDA/SCL -> exact I2C nets; C4 is fitted.
  • No daughterboard I2C pull-up resistors or multiplexer were added.
  • C5 is 4.7uF/10V on the 5 V entry; C6 is 4.7uF/25V on the 10 V entry.
  • R5 is specified as 51Ω, 1206, 0.5 W; dissipation still requires prototype/design confirmation.
ERC Status
22 floating-pin errors remain, all in the unwired CTA network: U1 signal pins, Q1, R1/R2/R3/R5/R6/R7. The already-connected connector, TSIC306, GY-906, decoupling, ground, and test-point sections passed the bounded connectivity inspection.
BOM

Table


Ref.QtyValue / PartManufacturer / MPNPackage / Footprint statusNotes
J11Micro-Fit 3.0 2x5 RAMolex 43045-1000 / 0430451000Right-angle THT; KiCad target specifiedVerify harness orientation/pin numbering before cable build
U11TLV27L2TI TLV27L2IDRSOIC-8CTA controller; signal network open pending reference circuit
Q11BC635 NPNonsemi BC635TBD - verify vendor lead formE-C-B pin naming recorded; no substitution
J21FS7.0.1L.195IST AG FS7.0.1L.195TBD - remote wire interfacePins Heater, Pt1200, GND
U21TSIC306IST AG 103489TBD - verify TO-92 lead formPin mapping connected as specified
MOD11GY-906 MLX90614 moduleTeyleten Robot B0CLDGFQYSTBD - measure physical moduleDisable onboard I2C pull-up jumpers
R111.2kΩ, 1%TBD0805Low-tempco precision CTA resistor
R21500Ω multi-turnBourns 3296W-1-501LFTHT trimmerCTA calibration
R31140Ω, 1%TBD0805Low-tempco precision CTA resistor
R5151Ω, 1%, 0.5WTBD1206Verify thermal margin
R6110kΩ, 1%TBD0805CTA network
R711.1MΩ, 1%TBD0805CTA loop stability
C11100nF X7R, 25VTBD0805U1 decoupling
C214.7uF X7R, 25VTBD0805CTA local bulk
C31100nF X7R, 10VTBD0805TSIC306 decoupling
C411uF X7R, 10VTBD0805GY-906 decoupling
C514.7uF X7R, 10VTBD08055 V connector-entry bulk
C614.7uF X7R, 25VTBD080510 V connector-entry bulk
TP_*10Test pointsGeneric0.5 mm test point currentlyIncludes optional TP_FS7_REF
Connector Pinout

Table


PinNetStatus
1+12V_SYSIntentional NC
2PWR_GNDIntentional NC
3+10V_ANALOGConnected
4AGNDConnected
5FLOW_OUTConnector/test point only until CTA wiring is resolved
6+5V_LOGICConnected
7DGNDConnected
8TSIC_DATAConnected
9I2C_SDAConnected
10I2C_SCLConnected
Custom Symbols / Footprints
Symbols present or project-specific
  • FS7.0.1L.195 three-pin remote sensor/interface
  • TSIC306 TO-92, pins GND/SIGNAL/VDD
  • Teyleten Robot GY-906 four-pin module
Footprints still required or to be verified
  • FS7 board-side wire/connector interface
  • Exact TSIC306 TO-92 lead form
  • Exact BC635 vendor lead form
  • GY-906 module footprint measured from the purchased B0CLDGFQYS board
Open Item Required to Complete the Schematic
Provide the existing FS7 CTA circuit drawing referenced in the requirements, or a legible IST application-note figure showing every U1/Q1/R1-R7/FS7 connection. Once supplied, only the CTA wiring and a final ERC pass remain; no PCB layout is needed.
  • Current Status

  • Verified Connectivity

  • ERC Status

  • BOM

  • Connector Pinout

  • Custom Symbols / Footprints

  • Symbols present or project-specific

  • Footprints still required or to be verified

  • Open Item Required to Complete the Schematic