Do not release this PCB for prototype fabrication yet. The board is valid and the routing engine reports no fundamental routing-feasibility anomaly, but it remains essentially unrouted and two placement issues should be corrected before routing begins.
Current board state
Board: 28 × 90 mm, 1.30 mm thick, four copper layers.
Layer intent: Top signal/components, L2 solid GND, L3 power plane, Bottom signal/components.
Review complete: the four-layer board is routable in principle, but not ready for fabrication. Two blockers must be fixed first: L1 is about 29 mm from U2’s switching pins, and the BLE antenna needs edge placement plus an all-layer keepout; 174 airwires remain.
Status: Rechargeable-power schematic and preliminary PCB placement implemented and verified. A parametric build123d enclosure prototype is now implemented; PCB routing remains outside this mechanical task.
Outdoor BLE pool-filter pressure monitor with a sealed USB-C charging interface and a protected 1S2P cylindrical Li-ion pack.
Preserve pressure monitoring, BLE, one-year history, button gestures, RGB status, buzzer alarm, 3.3 V logic, and switched 5 V transducer excitation.
Battery and Charging Architecture
Pack selection: two physically separate, same-lot Samsung SDI INR18650-35E cells used together as one 1S2P pack, 3.60 V nominal and 4.20 V full. Minimum cell capacity is 3350 mAh; maximum can dimensions are Ø18.55 × 65.25 mm. Procure as a qualified UK/EU pack-assembler welded assembly, not user-soldered bare cells.
Cells must be factory-tabbed or joined by a qualified spot-welded harness. Do not solder directly to bare cell cans.
J1 (Cell A) and J7 (Cell B) are separate three-wire JST GH interfaces. Each uses pin 1 for cell positive, pin 2 for CELL_NEG_RAW, and pin 3 for its individual NTC lead; connector pins 4/5 are mechanical anchors. Each cell positive passes through its own F2/F3 1206L075THYR PPTC before the branches join at BAT_PACK.
Both cell-negative conductors join only at CELL_NEG_RAW, upstream of Q3. System GND remains the protected PACK- side of Q3, so neither cell branch bypasses the shared BQ29700 + FS8205A low-side protection path.
U7 BQ29700DSER plus Q3 FS8205A provides board-level overcharge, over-discharge, charge/discharge overcurrent, and short-circuit protection. BQ29700 thresholds are 4.275 V OVP, 2.8 V UVP, ±100 mV overcurrent thresholds, and 0.5 V/250 us short-circuit detection. Firmware enters low-battery shutdown near 3.0 V so 2.8 V remains an emergency cutoff.
Do not use an additional protected-pack PCB in series unless its behavior is explicitly reviewed; duplicated protectors can interfere with charging and fault recovery.
USB Input and Power Path
The enclosure uses Bulgin PXP4043/C, a 4000-series sealed panel USB-C receptacle with all 24 Type-C contacts on two rear 12-way headers. Use PXP4083 when unmated and preferably PXP4041/C/C/1M00 as the sealed charging lead. J6 remains the PCB-side four-wire interface: combined VBUS, combined GND, A5/CC1 and B5/CC2.
R32/R33 are independent 5.1 kΩ USB-C sink pull-downs. The panel assembly must pass CC1 and CC2 through to J6. If a future panel assembly outputs only VBUS/GND, it must contain its own compliant sink termination and R32/R33 must not be duplicated.
No USB-PD and no USB data are implemented. The design requests only the default 5 V Type-C source.
F1 Littelfuse 1206L075THYR is a 0.75 A hold PPTC. D2 TPD1E10B06 provides low-leakage 5.5 V ESD protection. U6 provides input OVP, reverse-current blocking, short-circuit protection, and inrush/current limiting.
U6 BQ24074RGTT provides dynamic power-path/load sharing so the monitor operates while plugged in. OUT is SYS_PWR, approximately BAT voltage on battery and regulated near 4.4 V with valid USB input.
U2 SGM62112-3.3 remains valid from the protected 1S range through 4.4 V SYS_PWR. U3 MP3416 remains valid and supplies switched 5 V to the transducer.
Charger Configuration
U6 is fixed in USB500 mode: EN1 pulled high by R25 and EN2 grounded. Total input current, including system load and charge current, is limited to 500 mA maximum.
R24 = 1.78 kΩ programs nominal 500 mA fast-charge capability from KISET = 890 AΩ. Actual battery current is normally below 500 mA because input current is shared with the system and may be reduced by VIN-DPM or thermal regulation.
C13 = 1 uF at IN, C14 = 10 uF at OUT, and C15 = 10 uF at BAT.
ITERM is left open for the default 10% termination threshold, approximately 50 mA. ILIM is unused because fixed USB500 mode is selected.
The BQ24074 hardware safety timer cannot accommodate a deeply depleted 5.2–7.0 Ah parallel pack at a 500 mA USB ceiling, so TMR is grounded to disable the internal timer. R34 enables a firmware backup timeout: CHARGE_ENABLE_N defaults low/enabled and U1 P0.12 can drive it high to stop charging after a cumulative 24-hour charge session or detected abnormal behavior.
This timer decision requires validation and a formal safety review before production; charge termination, NTC qualification, charger OVP/thermal regulation, and BQ29700 pack protection remain active independently.
Temperature Qualification
T1 and T2 are individual Semitec 103AT-2 10 kΩ NTCs located physically against Cell A and Cell B, under compliant insulation and strain relief. Each NTC returns through its cell-negative harness conductor.
U8 TLV7044 provides four nanopower open-drain comparators: hot and cold qualification for each cell. R35/R36 = 10 kΩ form the NTC dividers; R37/R38 = 36.5 kΩ/100 kΩ set the approximately 0°C cold threshold; R39/R40 = 240 kΩ/100 kΩ set the approximately 50°C hot threshold. Either cell hot, cold, open, or shorted asserts TEMP_FAULT_SINK.
R41 = 10 kΩ holds U6 TS at approximately 0.75 V from its 75 µA bias current during a valid condition. A fault from U8 sinks TS through R42 = 1 kΩ below the 0.3 V hot threshold, so either unsafe cell independently inhibits charging in hardware.
Q4/Q5 enable TEMP_MON_SUPPLY only while USB_5V_FUSED is present, eliminating the roughly 0.4 mA continuous drain that two always-on 10 kΩ NTC dividers would impose during battery operation. The temperature monitor starts far faster than the BQ24074 50 ms TS deglitch interval.
R43/R45/C20 and R44/R46/C21 provide microamp-limited, scaled observations on CELL_A_TEMP_ADC and CELL_B_TEMP_ADC. These readings are valid while USB is present; hardware U8/U6 remains the primary charge lockout.
Power Tree
Diagram
Runtime and Charge Expectations
Samsung INR18650-35E pack capacity is 6.70 Ah guaranteed minimum and 6.90 Ah typical planning value. The 70% usable-capacity cases are 4.69 Ah and 4.83 Ah.
With the preferred one-second breath every 20 seconds, estimated green runtime is approximately 4.04 years guaranteed and 4.16 years typical. Persistent red with duty-limited buzzer is approximately 1.64 and 1.69 years. Cell calendar aging and maintenance policy will likely dominate these theoretical values.
Ideal 500 mA charge times including 20% CV/termination allowance are 16.08 hours guaranteed and 16.56 hours typical. Practical sealed-enclosure target is approximately 18–23 hours because input current is shared and thermal regulation may reduce charge current.
Preserved Monitoring Functions
Pressure sampled every 15 minutes from an external 0–30 psi, 0.5–4.5 V ratiometric transducer powered from SENSOR_5V_SW.
Green below +10%, yellow +10% to =+20% above stored clean-filter baseline.
One approximately one-second breathing pulse every 20 seconds; buzzer is periodic and duty-limited only in red.
U4 provides 16 Mbit SPI history storage. User gestures are generated by a separate enclosure-mounted, normally-open momentary RGB illuminated pushbutton connected through J8; the former U5 Hall switch and LED1 onboard RGB LED are removed.
Remote Waterproof User Interface
J8 drives SCHURTER MSM II article 3-155-526, a 19 mm momentary SPDT switch with common-anode RGB ring. The front is IP66/IP67; the exact variant is IP40 at the rear, so its quick-connect terminals must remain inside the gasketed enclosure and receive a sealed boot/potted strain relief. The JST GH fly lead still mates with GHR-06V-S and SSHL-002T-P0.2 contacts.
J8 pinout: 1 SW_IN, 2 GND/SW_RETURN, 3 LED_R, 4 LED_G, 5 LED_B, 6 LED_COMMON. LED_COMMON is 3V3 through removable 0 ohm link R50. The required button LED is common-anode and its normally-open switch closes SW_IN to GND/SW_RETURN.
D3 TPD4E05U06 protects SW_IN and the three LED cathode conductors. R51 = 1 kOhm isolates the cable-side SW_IN node from SW_IN_MCU. R10 = 100 kOhm pulls SW_IN_MCU high and C11 = 100 nF filters it; firmware supplies final debounce and gesture timing.
P1.08 is the active-low low-power SENSE/wake input. P0.13/P0.14/P0.15 remain active-low PWM cathode drives for red/green/blue. R11 = 820 ohm targets about 1.2-1.7 mA red; R12/R13 = 680 ohm target about 0.2-0.7 mA green/blue for LED dies around 2.8-3.2 V. R14-R16 pull the cathode-drive nodes high so all colors remain off while the MCU pins are high impedance.
SCHURTER 3-155-526 has a common LED anode and separate R/G/B cathodes, directly matching J8. LED Vf at 10 mA is 1.7 V red and 2.6 V green/blue, with maxima 2.4/3.2/3.2 V. Existing resistors remain electrically safe; validate brightness through the actual ring in direct sun.
Gestures remain: single press takes a fresh reading and updates status/BLE; double press mutes only the audible red alarm for 24 hours; 3 s hold performs stable multi-sample clean-filter calibration; 10 s hold requests factory reset and requires release plus another press within 5 s before erasure.
Firmware-Relevant Power Pins
P0.03/AIN1: CELL_A_TEMP_ADC, scaled Cell A NTC voltage; valid while USB input enables TEMP_MON_SUPPLY.
P0.02/AIN0: CELL_B_TEMP_ADC, scaled Cell B NTC voltage; valid while USB input enables TEMP_MON_SUPPLY.
P0.12: CHARGE_ENABLE_N, drive high to disable charging; R34 defaults it low/enabled.
P1.08: SW_IN_MCU, active-low remote button input with low-power SENSE wake. P0.08 is intentionally unused after removal of the Hall switch.
Mechanical, Sealing, and Cell Safety
Retain the 28 mm x 90 mm four-layer central PCB concept and two longitudinal cell channels on either side.
The top panel contains SCHURTER 3-155-526 (front IP66/IP67, rear IP40 inside a sealed boot), Bulgin PXP4043/C with PXP4083 cap, and the gasketed screw-cap seal. Both internal harnesses require strain relief; no Hall activation zone or onboard light pipe is required. The transducer connection remains at the opposite end.
Final PCB placement must put J1 and J7 at opposite cell-facing long edges, with F2/F3 immediately inside the connectors and short, symmetric BAT_PACK branches. The antenna zone must remain free of cells, metal tabs/contacts, wiring, buzzer, ground/power copper, and filled encapsulant.
The 70 PCB-mounted parts occupy both sides: all ICs/connectors are top-side and many small passives are bottom-side. The 28 x 90 mm outline remains feasible for placement but is routing-dense; route feasibility and battery-carrier clearance must be reassessed before committing the enclosure diameter.
Cylindrical cells must not be rigidly imprisoned in hard potting compound. Use a low-modulus, electrically insulating, thermally qualified and flame-retardant compliant material around cell channels, while preserving cell vent paths, expansion allowance, removable/serviceable pack strategy, and strain relief.
Do not obstruct positive-terminal safety vents or create a sealed pressure vessel around a failing cell. Define vent direction, pressure relief, water-ingress tradeoffs, and regulatory transport/service requirements during enclosure design.
Avoid conductive, metal-filled, carbon-loaded, or high-dielectric encapsulants near the BLE antenna. Validate RF range with the actual compound, wet enclosure, cells, tabs, and cable installed.
Open Safety and Mechanical Decisions
Qualified pack-assembler drawing and incoming inspection for the controlled Ø19.25 × 70.00 mm insulated/tabbed Samsung INR18650-35E branch envelope; F2/F3 hot-ambient trip behavior and branch voltage drop still require prototype validation.
Bulgin PXP4043/C P2/P3 header mating details, conductor gauge and minimum cable bend radius are not published; qualify the production adapter harness from a controlled sample/drawing.
Thermal performance of U6 at 500 mA inside the sun-heated sealed tube; copper area and thermal vias must be validated.
Final battery-to-antenna spacing, top-stack geometry, venting strategy, compliant encapsulant, and service-life policy.
SCHURTER 3-155-526 rear-terminal boot/potting method and direct-sun ring visibility. Existing R11-R13 are electrically safe, but brightness changes may still be required after prototype testing.
Mechanical Prototype Implementation
Three separate build123d assets remain placed around the real 28 × 90 × 1.30 mm PCB datum: sourced-hardware body, removable cap and replaceable M20 adapter. See Enclosure Build for linked assets and calculations.
Final enclosure-only envelope is 84 mm wide × 149 mm long × 46 mm maximum local height. The main 3 mm-wall tube is 78 × 120 × 30 mm; the exact-hardware service flange/neck plus cap is 84 × 23 × 36 mm total, providing rear-body clearance beyond the PCB edge.
Cell channels are sized to a controlled qualified-pack envelope of Ø19.25 × 70.00 mm around Samsung INR18650-35E maximum cans, with 0.35 mm radial FDM clearance and a 6 mm positive-terminal vent plenum before the BLE boundary.
Cap hardware is frozen to SCHURTER 3-155-526 and Bulgin PXP4043/C: anti-rotation button cutout 19.15 × 18.175 mm, USB cutout Ø19.15 mm and 5.5 mm effective panel thickness.
The cap seal is Dichtomatik/FST 67193633, BS136 50.47 × 2.62 mm peroxide-cured EPDM. Groove is 2.00 mm deep × 3.80 mm wide with 1.04% stretch, 17.32–25.93% tolerance-stack squeeze and ≤75.34% calculated gland fill.
The M20 adapter remains deliberately replaceable because the pressure-transducer seller has not supplied a manufacturer-controlled M20 drawing.
No IP67 claim is made from CAD. Required tests include immersion/leak, seal cycling, rear-button boot validation, outdoor UV/chlorine exposure, BLE range and sealed direct-sun charge thermal qualification.
Success Criteria
No primary-cell charging ambiguity: only a matched 1S2P rechargeable Li-ion pack may be connected.
Charging works while monitoring, suspends outside the qualified temperature range, terminates correctly, and can be disabled by firmware timeout.
Board-level protection interrupts overcharge, deep discharge, overcurrent, and short circuit.
No unresolved critical schematic or placement errors; unrouted airwires remain expected until routing is authorized.