Routing / Manufacturing Readiness Status
Date: 2026-06-28
Current status
The board is not ready for manufacturing export.
Functional scope clarification
- Cellular/BG95/SIM functionality is intentionally removed.
- The remaining card connector is
MICROSD1 and is for microSD only, not a SIM card.
- Stale cellular/SIM ground marker references removed on 2026-06-28:
U1 EP - U7 USIM_GND, U7 GND - C25 P2, U9 GND - U10 GND, and IC4 GND1 - IC5 GND1.
- Former
J1 was renamed to MICROSD1; editable properties now classify it as a memory connector / microSD SPI connector.
Blocking issues
- 2026-06-28 microSD routing cleanup:
MICROSD1 was replaced with true Hirose microSD connector DM3AT-SF-PEJM5, local overlapping copper under the new footprint was removed, and autorouting restored the microSD SPI/3V3 connections. ERC and BOM/manufacturing checks are clean after this cleanup.
- Airwires review still reports 2 GND fill/stitching errors on generated GND copper objects:
93ff487a-5fff-4241-a8c7-7caf450d1d70.fill to GND trace 61265950-4851-4397-a90e-b522049da0c7
93ff487a-5fff-4241-a8c7-7caf450d1d70.via.stitch.47 to U6/AGND-related GND pad 2f218ce3-0a8c-48b5-81b5-8418dcaa7f1d__89903b65-6b02-4f01-b571-e273770f097a
- Auto-route/pre-route check previously reported
ROUTING_NOTHING_TO_ROUTE, so automated routing cannot repair these airwires.
- The issue appears to be generated GND fill/stitching connectivity recognition, not an ordinary missing signal trace.
- Full DRC still also reports one non-microSD airwire involving
Trace 00f8; this is outside the microSD connector cleanup scope and should be reviewed separately before export.
Attempted remediation
- Tried deleting the specific generated stitching via by UID and by resolved designator (
Via-Island-47); available layout deletion tools could not resolve/delete that generated object.
- Tried disabling only the reported generated stitching via via layout rules; Airwires still reported the same 2 errors, so the change was restored.
- Earlier remediation attempts on local GND copper bridge pads and direct-connect rules did not clear the issue or created other DRC/manufacturing blockers.
Recommendation
Do not export manufacturing files yet. The remaining GND airwires require a Flux UI/backend action to regenerate or remove the generated GND copper fill/stitching objects, then rerun Airwires, Overlapping Copper, Floating Copper, and pre-route checks. If escalating to Flux support, include the fill UID 93ff487a-5fff-4241-a8c7-7caf450d1d70.fill and stitching via UID 93ff487a-5fff-4241-a8c7-7caf450d1d70.via.stitch.47.