Chat


How can I help you?

Explain project
Write a project description
Find schematic issues

Surgical Routing DRC Repair Report
Scope and baseline
  • Baseline: commit #701d1003.
  • Placement constraint: immutable; no component position, rotation, or layer edits permitted.
  • Requested targets: U3:GND::1 ↔ C15:P2, Trace 5967 ↔ S1:2, and four C26 pad-2 copper overlaps.
  • No DFM checks or manufacturing exports were run.
Item status

Table


Scoped itemStatusResult
Clear four C26 pad-2 overlapping-copper errorsCompletedRemoved only the four offending old-footprint routing objects: I2S_BCLK smart via at (5.5953, 23.1526), its local Top segment, and two stale 3V3_SYS/old-land trace segments. Final overlapping-copper count: 0.
Restore routing affected by C26 cleanupPartially completed3V3_SYS was rerouted successfully with a 5.799 mm, two-layer route and one via. The unaffected downstream I2S_BCLK Top chain was reconstructed; the remaining local bypass could not be completed without new overlaps.
Route GND U3:GND::1 ↔ C15:P2Failed after two genuine approachesApproach 1: direct 0.10 mm deterministic route, blocked-no-path. Approach 2: through-hole via-at-U3-pad/L2 escape followed by 0.10 mm route to C15:P2, also blocked-no-path; the unsuccessful via was removed. L2 was not used for signal routing and remains the GND plane.
Route REG_EN Trace 5967 ↔ S1:2Failed after two genuine approachesApproach 1: 0.254 mm route from Trace 5967 to S1:2, blocked-no-path. Approach 2: 0.10 mm route, blocked-no-path. No global rule relaxation or placement change was made.
Final DRC readback
Review timestamp: 2026-08-15T22:20:54.388Z.
  • Airwires: 3 errors
    1. I2S_BCLK local gap: via c066192b… ↔ Trace 8642….
    2. GND: U3:GND::1 ↔ C15:P2.
    3. REG_EN: Trace 5967 ↔ S1:2.
  • Overlapping copper: 0.
  • Dangling traces: 1 warning — the reconstructed I2S_BCLK downstream chain (Trace 8642 group), pending the local bypass.
  • Component overrides: 66 warnings (pre-existing authoritative footprint/placement overrides).
  • Edge placement: 1 informational (J1).
  • All other requested DRC categories returned no findings: overlapping fills, overlapping traces, floating copper, invalid layer, missing footprints, under-connected via, stackup validation, component outside board, component-body overlap, pad-access clearance, GND return loop, trace-corner radius, protected intrusion, deprecated rules, and board density.
Blocker evidence
  • GND failed both a direct 0.10 mm path and a distinct via/L2-plane escape approach.
  • REG_EN failed both normal-width and 0.10 mm neckdown path searches.
  • I2S_BCLK failed two pathfinder attempts to the original downstream endpoint; a manual Bottom-layer bypass was then tested but generated nine copper overlaps and was atomically reverted.
  • Placement changes and global manufacturing-rule relaxations were prohibited, so no further upstream remedy was permissible within scope.
Immutable-placement audit
Change-history path inspection from #701d1003 shows only net child lists and trace/via node paths. No component position, positionX, positionY, rotation, rotationZ, or layer property path changed. The temporary unsuccessful I2S bypass was reverted, and the temporary GND via was deleted. Immutable-placement audit: PASS.
Net result
The C26 copper-overlap defect is fully cleared and the collateral 3V3_SYS break is repaired. The batch is not fully complete because three airwires and one related dangling-chain warning remain under immutable placement and unchanged global manufacturing rules.
  • Scope and baseline

  • Item status

  • Final DRC readback

  • Blocker evidence

  • Immutable-placement audit