Chat


How can I help you?

Explain project
Write a project description
Find schematic issues

Authorized Part Edit Report
Date: 2026-08-15
Completion status
  • S1 — completed
  • C24 — completed
  • C26 — completed
  • Routing / trace edits — unattempted as required
Selected parts and live stock evidence

Table


RefSelected manufacturer partLCSCLive LCSC evidenceElectrical ratingMechanical dimensions / height
S1G-Switch MK-12C02-G015C29115199,440 in stock; ships now on the live LCSC product pageSPDT, surface-mount, right-angle / side-actuatedPackage 6.6 × 1.4 mm; switch height 4.2 mm; G1.5 actuator
C24Panasonic 6SVPC330MC1395691,040 in stock; ships now on the live LCSC product pageConductive-polymer aluminum, 330 uF, 6.3 VØ6.3 × 5.9 mm case; axial/seated height nominal 5.9 mm, datasheet maximum 6.0 mm
C26Lelon OCV101M0JTR-0606C1348542,795 in stock; ships now on the live LCSC product pageOrganic conductive polymer, 100 uF, 6.3 VØ6.3 × 5.9 mm case; axial/seated height nominal 5.9 mm, datasheet maximum 6.0 mm
Preserved schematic connectivity

Table


RefPreserved connections
S1Pin 2 (common) → REG_EN; pin 3 (throw) → SYS_RAW; unused throw pin 1 remains No Connect. Library terminals 4–7 are mechanical/shell pads and are marked No Connect.
C24Pin 1 → 3V3_SYS; pin 2 → GND
C26Pin 1 → 3V3_SYS; pin 2 → GND
Resolved transform readback
  • S1: X +22.00 mm, Y +39.00 mm, Top, rotation 180°. The library footprint's side actuator projects toward local −Y; 180° points it toward the +Y board edge/wall.
  • C24: X −13.00 mm, Y −27.00 mm, Top, rotation 0°.
  • C26: X +9.00 mm, Y +22.50 mm, Top, rotation 0°.
Verification
Direct schematic readback confirms the selected MPN/LCSC properties and restored net memberships for all three references. Direct PCB readback confirms the exact position/layer/rotation rules above. No routing tool or trace-edit operation was used.
The board checker flags S1 as extending outside the rounded board outline at the exact authorized center; this is consistent with the requested +Y wall-exiting actuator. Placement also surfaced copper-overlap warnings around replacement footprints; they were not remediated because this scope explicitly prohibits trace edits and moving other components.