The switch now faces the top button correctly, and I’ve fixed the two-layer setup reference and internal programming-header edge check. The button still has too much gap to actuate reliably, so I’m adjusting the enclosure interfaces next.
I corrected the switch orientation and PCB setup, cleared the lid-screw entries, and added recessed USB access; results are recorded in the PCB Placement Report and Project Specification.
The design remains blocked: verification found a real switch/support collision, insufficient button travel, and obstructed diffuser installation—earlier zero-overlap results were incorrect, so I have not started routing.
INCOMPLETE — NOT READY TO PRINT, ORDER, OR FREEZE ELECTRONICS. The additional authorized repair pass is consumed: 3 repair cycles overall; no fourth repair attempted. Only the independently verified USB-lid recess and six screw-entry cuts were applied. The coupled support, split-retainer and compliant-actuator candidate failed preflight and was withheld rather than installed with known new interference. Completion of this review is not completion of the assigned repair batch or the overall project.
This section supersedes the historical report below and any earlier zero-intersection claim contradicted by the explicit-solid checks. The actual PCB and all 17 component models, placements and orientations remain fixed. No schematic, routing, outline, stackup, component, reservation, specification, or industrial-design-brief edits were made.
Assigned items
Table
Item
Result and specific blocker
Preserve PCB/component state and approved shell silhouette
Completed. PCB export and all 17 component scene records compared equal before/after the lid change; subsequent mutation replaced only the ROOT body model. Shell remains 100 × 42 × 32 mm, R9.
Restore access to recessed USB4960-00-C
Completed for nominal housing geometry. Rear lid v3 has an exterior pocket and inward reinforcement; cable-specific mating remains UNVERIFIED.
Clear six lid-screw entry paths
Completed. Enclosure body v3 applies only six post-union Ø2.4 mm cuts; final STEP entry and pilot probes are empty.
Relocate support clear of SW1
Failed / candidate withheld. Candidate clears SW1 but its upper support ledge intersects the new actuator by 1.745897 mm³. Existing support remains unchanged and overlaps actual SW1 by 17.588207 mm³.
Correct actuator travel/compliance/tolerances
Failed / candidate withheld. Static interference prevents qualification. Existing actuator has about 0.399988 mm gap and only 0.5 mm cap travel.
Replace obstructed retainer with serviceable retention
Failed as an integrated solution / candidate withheld. Two candidate rails pass sampled axial paths but approach J2 to 0.711218 mm, below the required 2.0 mm component clearance; diffuser insertion itself remains blocked.
Final placed-geometry inspection and report
Completed, with failures. 329 pair records, pipeline STEP probes, native model-node readback and inspected exterior CAD view.
Full moving/flexed actuator qualification, physical assembly, print coupons and cable trials
Unattempted after static preflight failure; no physical hardware was available.
Unattempted, outside this assignment; no new support reservations are accepted.
Applied changes and current asset versions
3D Model
: original supports, locators, button opening and diffuser pocket retained. The sole geometric change is the six screw-entry cuts at (−40,−18), (0,−18), (40,−18), (−40,18), (12,18), (40,18), starting z=5.1. Comparison with the prior body shows 0 mm³ added and 23.709040 mm³ removed. Final STEP: valid single solid, 100 × 42 × 29.6 mm, volume 25828.424691 mm³.
3D Model
: 16 × 10 mm R1 exterior pocket centered (0,−6), floor z=6.2, with a 0.6 mm entrance flare. A 20 × 14 mm local pad reaches inward to z=3.8, retaining 2.4 mm floor thickness around the existing 9.6 × 4.9 mm through-aperture. Exterior remains z=9.3. Final STEP: valid single solid, 100 × 42 × 5.5 mm, volume 11142.296941 mm³.
Diffuser insert v1, Diffuser retainer v1, Button actuator v2 and all eight individual screw nodes remain unchanged. PCB placeholder v1 remains disabled. Six obsolete screw nodes remain disabled and without assets.
Both new models read back under ROOT at (0,0,0), rotation (0,0,0), scale 1, Z-up, enabled by default. Native scene has a common +0.8 mm Z render offset; it was removed for measurements, not authored into either source. PCB top datum remains z=0 and underside z=−1.6.
Two PCB screws remain at (−39,−11,0), (39,11,0). Six lid screws remain at the XY positions above, seat z=7.1. Same ST2.2×8 simplified hardware, no additional fasteners.
Verification correction and durable evidence
Error in the prior checking method: Boolean intersection directly against a relocated Build123d Compound can return an empty result although the solids intersect. A regression test with the diffuser shifted +10 mm gives direct-Compound result 0 mm³ versus 500.974221 mm³ when explicit placed solids are intersected. Both solids contain a point in the obstructed ledge region. Earlier Compound-based motion/fit results must not be used as proof of clearance without this correction.
The current checks flatten shapes to explicit solids, bake rigid rotations in Z/Y/X application order corresponding to the saved Rx·Ry·Rz convention, and preserve actual saved model offsets. Source units are mm. Reported overlap threshold is 0.001 mm³; distance reporting precision is 0.001 mm. The reconstructed board envelope matches verified outline, thickness and four mounting holes; J1/J2 pin intersections with that envelope are intentional because the envelope does not reproduce their plated holes. Solder fillets and production dimensional tolerances remain unverified.
Fixed 86 × 30 mm R3 board, 1.600 mm copper-face separation; unchanged board export and component model records. No extra mechanical Z offset.
retention-support
FAIL
Existing upper center support physically overlaps SW1 by 17.588207 mm³. Two PCB screws and two locators remain, but this is not a usable installed assembly.
interference
FAIL
SW1/body collision remains. Other final non-thread mechanical pair intersections are zero; zero nominal volume does not establish production clearance.
assembly-path
FAIL
Retainer/body intersections: +8 Z gives 275.216797 mm³; +18 Z gives 135.984646 mm³. Diffuser/body at +10 Z gives 500.974221 mm³. No alternative tilted or flexed diffuser path is qualified.
screw-entry repair
PASS, nominal geometry
All six Ø2.4 mm entry probes z=5.1…6.9 and Ø1.7 mm pilot-interior probes are empty. Each 1 mm floor probe is fully solid: 2.010619 mm³. Remaining screw/body overlap is the modeled thread engagement: 8.376271 mm³ per lid screw, 8.934690 mm³ per PCB screw.
full fasteners-bosses compliance
FAIL / incomplete
Entry defect is fixed, but existing sharp support-root transitions and unchamfered locator tips do not establish the required root-fillet/locator detail. Exact purchased head/tool envelopes and torque are unverified.
connector-openings
PASS for tested nominal housing envelopes; UNVERIFIED for selected cable
Actual J1 face z≈6.5, outward +Z. Local pocket floor is 0.3 mm inboard of that face. J1/lid minimum distance 0.329210 mm at the intended interface, zero overlap. Other top components clear the lid by at least 2.950 mm.
controls
FAIL
Current rest gap 0.399988 mm leaves only about 0.100012 mm switch motion from 0.5 mm cap travel. The switch travel range extends to 0.4 mm. Current support collision independently blocks operation.
lid-joint
PASS for nominal seating and sampled opening path
Existing 3 mm engagement, 0.20 mm per-side clearance and recessed head seats preserved. Lid translations +0, 0.25, 0.5, 1, 2, 3, 5, 10, 20, 30 mm Z have zero interference with retained mechanics, board envelope and actual component models. This is sampled, not continuous motion qualification.
printability
UNVERIFIED / incomplete
PETG, 0.4 mm nozzle, provisional 0.2 mm layers. Upload reports 14 body and 7 lid down-facing planar faces. Accessible supports and protected fit surfaces need slicer review; printer/build volume unknown.
readback-export
PASS for node readback and individual pipeline STEP checks
Correct v3 sources, ROOT transforms and enabled states read back. Hardware nodes retained individually. A new combined STEP export and browser-editor visibility were not verified.
USB envelope evidence and limitations
A directly viewed USB Type-C R2.4 Figure 3-3 drawing informed a 12.85 × 7.0 mm rectangular overmold envelope and 8.28 × 2.43 mm shell envelope, using 6.55 mm shell protrusion for the tested access case. These numerical source facts are citation-unverified: the datasheet service remained evidence-pending after its timed wait, although the drawing was visually inspected. They are not a selected cable drawing and must not be represented as universal cable compatibility.
The overmold starts at z=6.5 in the conservative terminal access pose, and the shell extends inward from it; translations +0, 1, 3, 10, 30 mm along Z give zero housing interference. The plug approaches from +Z and inserts along −Z. These are separate clearance envelopes, not a solid exact electrical plug model: internal contact engagement, connector conformance, unusual overmolds, strain relief, cable bend radius, pull forces and physical seating remain unverified.
SW1 operating force is 260±50 gf and travel is 0.25±0.15 mm. Retrieved specifications do not supply a usable allowable-overtravel or maximum-actuator-load limit; this remains unresolved. 0.4 mm maximum operating travel is not a certified safe overtravel limit.
Withheld candidate and handoff to the lead
The following are unplaced development sources, not current parts or approved replacements:
3D Model
3D Model
3D Model
3D Model
The failed bundle proposed auxiliary supports at (−8,−12), (8,12); two narrow rails centered x=±30; and 1.2 mm bearing arms below the PCB at the four corner holes. It shortened corner bosses to z=−2.8 and used the retainer arms as bearing spacers to preserve PCB underside z=−1.6, giving nominal 5.2 mm screw engagement. This is a deliberate departure from direct one-piece boss bearing and has not been accepted or applied. Both rail axial paths sampled at 1 mm increments over +0…40 Z were clear, but right rail/J2 clearance is only 0.711218 mm.
The proposed actuator had 0.15 mm rest gap, 1.5 mm cap stroke, an 11.3 × 8 × 1.2 mm PETG cantilever and secondary nose stops. It intersects the upper support ledge in x=5.5…6.225753, y=16.8…18, z=−10.6…−8.2. No deformed-pose, force, return, overtravel, fatigue, or full control insertion qualification followed this static failure. An illustrative beam-strain estimate at 1.35 mm deflection is about 1.90%, but it is not material or mechanism qualification.
No revised PCB keepouts should be committed from this bundle. Current support locations remain (0,±12), current retainer landings (±30,±13), with four corner holes unchanged. If a later authorized design uses the candidate bearing arms, their nominal underside footprint spans x=27…41.375 (and its mirror), y=8.625…13.375 (and its mirror), and it must first be rerouted mechanically away from J2. An upper auxiliary support nearer x=10 is only a possible next study, not an accepted location. The lead owns any specification or reservation updates.
The next authorization must address the diffuser's own installation path, not merely split the retaining ring; remove SW1/support interference; resolve the actuator/ledge collision and actuator assembly/overtravel; and maintain at least 2.0 mm clearance to J2. These are specific blockers, not permission for another repair in this pass.
Visual and physical validation status
The lid exterior was inspected in a CAD render with the inactive PCB placeholder explicitly excluded. The first unfiltered view included that disabled node, so one filtered display correction was made. The image below shows the new lid before the later hidden screw-entry-only body cuts; those cuts do not change the exterior silhouette and were checked by final STEP probes rather than another render.
Recessed rear USB access
Body print orientation remains front rim on bed, rear opening up; lid exterior on bed, build inward. Pocket, ledge and bore supports must be removable and must not damage seating/mating faces. No new snap or flexure was installed. Required physical work remains printed fit and support-removal trials, fastening torque, cable mating, optical uniformity, control force/travel/return and life, material strength, thermal behavior and cable-force stability. No IP or lifetime claim is made.
Historical report — superseded by cycle 3 above
The following records the earlier boardless phase only. Old static-pass statements are not current acceptance evidence; model links may follow the latest asset versions automatically.
Historical status and scoped result
Best validated candidate — NOT READY TO PRINT OR FREEZE ELECTRONICS. The full board-less separate-part assembly has been created and placed. The assigned definition of done is not met, because the final assembly-path and fastener-entry checks found functional errors after the two permitted repair cycles. Overall project/electronics completion is separate and was not attempted.
Table
Assigned item
Result
Read accepted spec/brief; preserve silhouette, one window/top button/rear lid/port
Upload and place complete assembly; datum, scale and model references read back
Completed: 14 rendered model nodes, no actual board
Sourced candidate connector and switch direction
Completed nominal research; exact fit and USB procurement remain unverified
Installed STEP overlap and motion checks
Completed; static non-thread overlaps eliminated
Retainer assembly/service path
Failed: straight insertion/removal blocked by support ledges and rear bosses
Lid screw unobstructed entry paths
Failed: locating lip intersects screw entry above blind boss
Actual switch/support compatibility
Failed design reconciliation: intended bottom-side switch zone overlaps top-center support
First-pass assembly ready to constrain electronics
Failed: requires another authorized mechanical repair pass
Schematic, actual outline, components and routing
Unattempted, intentionally outside scope
Blocking findings
Error — optical retaining frame cannot follow the tested rear insertion/removal path. Final-position overlap is zero, but translating the frame +8 mm along Z produces 275.216797 mm³ intersection with the body; at +18 mm, 135.984646 mm³. A tilted path was not qualified. Split removable retainers or revise support topology in a new authorized pass; do not claim the installed fit proves serviceability.
Error — rear screw entry intersects lip. The blind pilot itself is clear, but the body lip occupies part of the Ø2.4 mm entry cylinder between z=5.11 and 6.89. At the (0,-18) axis the obstruction is 3.918027 mm³. The 91-pair summary calls screw/body intersections intended threads; this additional check supersedes that broad classification for the upper lip. Cut a correctly sized entry after final unions in a new authorized repair.
Error — proposed TL3330 bottom-side placement is incompatible with the body support centered at (0,+12). Candidate switch body occupies the same underside zone. Its exact footprint/model placement has not been implemented. Relocate support while maintaining ≤50 mm spans, or revise the actuator/switch arrangement. Current stem motion clearance is not proof of switch fit.
Warning — actual USB 2047110101, selected cable overmold, exact screw head, print fits and optical behavior remain unverified. The same-family connector shell proxy clears the rear opening, but is not the exact board-thickness variant. No plug/cable bend qualification or production fit claim.
Datum and form
All authored dimensions in millimeters. All non-hardware nodes at ROOT position (0,0,0), rotation (0,0,0), scale1, zIsUp=true. PCB top z=0, underside z=-1.6; front is -Z, rear +Z, physical up +Y. Desktop is y=-21. An upright rendering maps project (x,y,z) to world (x,-z,y+21); this is not a PCB relocation.
Estimated shell 100 W x42 H x32 D, x±50/y±21/z[-22.7,9.3], R9. Ratios H/W=.42, D/H=.762, R/H=.214 match accepted drawing ranges. Button adds 2.5 mm above body, total44.5 mm. Freestanding bottom flat extends approximately82 mm across X with32 mm depth; actual stability with cable forces not tested.
Estimated PCB 86x30x1.6 R3 at origin. PROVISIONAL Ø2.4 holes (±39,±11), 4mm bounding-corner inset. Two diagonal screws at (-39,-11),(39,11), two locators at other corners. Body supports also (0,±12); retainer bears at (±30,±13). Generic component ceilings: top/rear4.9 mm, bottom/front4 mm, away from mechanical keepouts. USB special face9.05 mm; bottom-side LEDs face -Z. Diffuser inner face z=-18.3 yields mixing gap12.7 mm with4mm-high bottom LED,14.7 mm with2mm LED. Brightness/hotspots unverified.
Port aperture9.6x4.9 R2.2 centered(0,-6), rear exteriorz9.3, outward +Z. Candidate facez9.05 gives nominal0.25mm recess. Button Ø12 opening centeredx0,z-5, y18..21, capØ15, press -Y,0.5mm allowed motion. Nominal switch face(0,15,-3.35), stem facey15.1. All interface positions PROVISIONAL until actual electronics verification.
Source evidence and component direction
Molex official 204711 series table distinguishes 2047110001 (1.4mm tabs/recommended0.70mm PCB) from 2047110101 (2.5mm tabs/recommended1.60mm PCB). Exact variant nominal data is manufacturer web evidence, not a qualified assembled fit.
3D Model
measured8.94mm wide,4.60mm overall including tabs,10.45mm Z including tails. Placed proxy translation(0,-6,3.825) gives facez9.05 and lower tailz-1.40. Same-family shell geometry only; do not use its short tabs on the1.6mm board without requalification.
Molex customer drawing was viewed directly. The9.94x4.16 outline returned by a datasheet query belongs to the removable pick-and-place cap, not the installed receptacle; it was not used as the port size. The queried9.05mm face height was machine-unverified, although consistent with direct drawing and CAD datum. Treat this interface as nominal and unverified until exact0101 CAD/footprint review.
Library search found 0001 but not0101; a missing-part request was submitted. An alternate vertical direction is supported by stocked TE2337857-1 in the library, but it was not dimensionally substituted. Third-party0101 inventory listings exist; authorized-distributor small-quantity availability remains unverified.
E-Switch TL3330 manufacturer page lists TL3330AF260QG as a common surface-mount right-angle momentary SPST-NO configuration,7.8x2.5mm series outline.
3D Model
and manufacturer drawing were retrieved before actuator cuts. Actuator datum1.75mm above PCB and body height3.4mm were visually read from the drawing and remain unverified for exact placed fit.
TL3330 switch travel is0.25±0.15mm. A0.1mm nominal stem gap plus0.4mm maximum travel consumes the entire0.5mm actuator allowance; no tolerance margin is claimed. Physical calibration/overtravel test required. Library distributor snapshot showed Mouser5226 units of TL3330AF260QG; no purchase was made.
Separate assets and placement
Each source is parametric Build123d and compiles to one valid solid; derived STEP/STL downloads are available from its asset card.
Simplified ISO1478-family ST2.2x8 screws, steel finish, Estimated Ø4.2x1.7mm pan head with cross recess; helical threads omitted. Six lid +two PCB; no inserts. Six superseded screw nodes remain disabled and without asset references, because model deletion was unsupported. They are absent from final14-model scene and are not extra hardware.
Verification evidence
Upload geometry reports: body100x42x29.6; lid100x42x5.4; placeholder86x30x1.6; diffuser90x32x2; retainer93.6x35.6x16.7; actuator15x8.4x15; screw4.2x4.2x9.7mm. Every final STEP shape valid.
Final placed scene contains no board and14 models. ROOT parent, scale1 and correct positions read back separately. Browser editor visibility itself NOT VERIFIED; tool-rendered scene verified.
All91 pair distances and overlaps, measured from pipeline STEP files at saved scene transforms; distance tolerance0.001mm and nonintentional-overlap threshold0.001mm³. All non-thread static intersections zero after repairs. Screw/body overlaps8.934690mm³ each PCB,11.677202–11.677252mm³ each lid; upper lip obstruction exception described above prevents treating all lid overlap as acceptable thread engagement.
Fit/motion summary. Button/body overlap0mm³ at0,.25,.5mm press. Bare PCB/body overlap0 at Z translations0,2,5,10,20mm. These are sampled poses, not continuous swept-volume qualification.
Interface checks. Same-family USB proxy has0mm³ overlap with body/lid and0.329211mm minimum lid clearance. No selected plug model was tested.
Nominal clearances: retainer/body0.200000mm; actuator/PCB0.269258mm; actuator/lid1.486607mm; lid screw/PCB1.900000mm. Intended contacts at PCB supports, screw seats, diffuser/retainer and diffuser/body are0mm without volume overlap.
All eight blind pilot interior probes radius.85mm showed0mm³ body material; all1mm-deep floor probes radius.8mm were fully solid (2.010619mm³ each). PCB pilot floor z=-8.6, screw tip-8.0; body underside-10.6 gives2mm floor. Rear floorz=-1.2, tip-.9; boss bottom-3 gives1.8mm floor. These tests do not waive the upper-entry obstruction.
No actual PCB, package placements, netlist, or routing existed; electrical ERC/PCB DRC returned NOT CHECKED and does not validate this enclosure.
Combined CAD render
Placed enclosure
Opaque pale diffuser rendering is a geometry presentation, not predicted illumination or material transmittance. Rear view was also inspected for six recessed heads and USB opening.
Process, assembly and repair budget
Gray PETG #9a9a9a,0.4mm nozzle; nominal0.2mm layer PROVISIONAL. Ordinary walls3mm, rim/lid2.4mm; rear engagement3mm, radial slip clearance.20mm,1.3mm skirt,1.5mm lip; shadowline.5x.5mm. No vents/seal/IP claim. Printer and bed volume UNKNOWN; fit coupons required. Thermal adequacy, cable-force stability and service life unverified.
Planned print orientation: body front-rim plane on bed, rear up (+Z build); accessible support under internal ledges, top circular opening and rear bosses. Supports must not damage bores/seat faces. Lid exterior rear plane on bed, build toward -Z. Retainer ring plane on bed, columns up; actuator head face on bed, build along -Y; diffuser flat if printed, or cut/frosted sheet for better optical quality. Print transforms are separate from installed transforms. Retainer100mm-class diagonal and body100x42 footprint fit are unverified against the user's printer. No actual slicing was performed. Support topology and boss root transitions require further DFM review before release.
Intended assembly: diffuser → retaining frame → captive actuator/switch/PCB → PCB screws → rear lid and six screws. Do not execute this sequence yet: the tested retaining-frame path is blocked. The frame is positively retained in the installed state between diffuser and board, but assembly/serviceability is a separate failed gate.
Two focused CAD repair cycles used: (1) relocate/clip rear lid bosses and matching seats to clear PCB/button/lid; (2) relieve hidden actuator flange to clear upper central board support. Static checks then passed apart from intentionally modeled thread engagement, but late assembly-path/entry checks found remaining errors. No third repair was made. Request authorization before another geometry cycle; correct the three Error items together with exact connector/switch fit verification, then rerun affected interfaces and final placed scene.