USB4105-GF-A Guide


Created a project doc

USB4105-GF-A Application and Usage Guide

View Document

USB4105-GF-A Application and Usage Guide
The USB4105-GF-A is a 16-contact, right-angle, top-mount USB Type-C receptacle intended for USB 2.0 data and USB-C power connections. Its common use is as a reversible USB-C device/charging port, with duplicated D+/D− and power contacts supporting either plug orientation while CC1 and CC2 establish the port role and attachment state.
Verification note: GCT’s product page explicitly lists USB4105-GF-A as an orderable variant, while the attached product specification is written for the broader USB4105 series. Values cited from that specification therefore apply at series level; mechanical footprint dimensions must be checked against the exact USB4105-GF-A product drawing before fabrication.
1. Quick Specifications
Created and verified the USB4105-GF-A Application and Usage Guide. It includes cited specifications, pinout guidance, USB-C sink/source integration, PCB layout practices, pitfalls, alternatives, and sourcing information; unverified footprint compatibility is explicitly identified.
Please fix this, based from this flag issue:
The footprint exposes four separate GND terminals as adjacent/touching lands, but Flux connectivity produces two persistent, unrouteable GND airwires on terminal/pad UIDs ending 119cc761 and 56d71544, including a virtual stitching-via island.
I’ll inspect the ground-terminal mapping and footprint connectivity, fix the underlying cause without changing the connector’s land pattern unnecessarily, then check for remaining airwires.
The current footprint already has two combined GND lands—not four separate ones—and neither flagged UID is present, so I made no footprint changes and cannot confirm the airwires are resolved; findings are in the connectivity investigation.
What is the affected board’s Flux URL and connector designator so I can inspect the actual instance and stitching-via island?
"USB4105 Ground Connectivity Investigation" completed.
The source footprint already uses two composite GND lands, and neither flagged UID exists in this part project, so I made no changes. I can’t verify or clear the reported airwires from this source alone.
Please send the affected board’s Flux URL and connector designator so I can inspect the instance producing the airwires.

Waiting for input


Ground Connectivity Investigation
Status and scope
Inspected adrian95/usb4105-gf-a, source part UID e144d1e5-c996-4a7a-a01d-8049d0ab61fd, on 2026-10-19. Baseline/latest design commit was a76dae05 (2026-09-15). No schematic, pin-map, footprint, copper, mask, paste, shell, or property mutations were made. This document is the only project change.
  • Completed: source terminal inventory, footprint-asset mapping, computed pad geometry, symbol pin inventory, manufacturer drawing comparison, and available source checks.
  • Failed/blocked: reproduction and definitive diagnosis of the reported two unroutable GND airwires. UIDs ending 119cc761 and 56d71544 do not occur in the current source terminal/pad inventory. The supplied description of four separate GND terminals and 16 contact lands does not match this source state.
  • Unattempted: source repair, publishing, downstream instance replacement, and routing modifications. No supported source defect was identified to repair. No internal feedback was filed.
Findings and root-cause limits
The current source contains 12 contact pads plus four separately mapped shell stakes, not 16 contact pads plus four stakes. GND is already represented by two composite terminals, A1_B12 and B1_A12, each mapping to one rectangular copper land. VBUS similarly has two composite terminals. All eight other USB contacts have independent terminals and pads. The two GND lands are at opposite ends of the row and are not touching each other.
The manufacturer drawing sheet 1 distinguishes 16 connector contacts from 12 rectangular SMT solder lands: four 0.60 × 1.15 mm lands and eight 0.30 × 1.15 mm lands. The broad lands bear paired labels A1 B12, A4 B9, B4 A9, and B1 A12. This supports the existing composite GND/VBUS land representation.
The initial generic web-PDF summary incorrectly inferred 16 separate PCB lands from the 16 contact labels. That inference was rejected after direct raster inspection of the original drawing and a focused, evidence-backed datasheet query. No mutation was based on that summary.
There are zero schematic nets/wires, no route segments, no vias, no smart vias, and no net pour/island nodes in the source layout tree. A downstream virtual stitching-via island therefore cannot be diagnosed from this source footprint alone. The shared generic Terminal child pin UID 111bf4e4-02dd-41bb-a137-c0a32607d321 is present under every distinct terminal element; its repetition alone is not a duplicate source pad mapping.
Conclusion: the reported board instance, revision, override, or other part is inconsistent with the source inspected here. A platform copper-connectivity defect remains possible but is not established. There is no evidence-supported source-part edit that can be claimed to remove the reported airwires.
Exact mappings before and after
Before = after for every row. In this source project, each listed terminal element UID is also the corresponding mapped pad UID. Coordinates below are computed Flux source-layout coordinates in millimeters, not the KiCad asset's opposite-sign Y coordinate convention.

Table


TerminalPin number / footprint pad nameElement and pad UIDCenter x, y (mm)
GNDA1_B120e2788ea-4377-4885-b655-ab172818f70b-3.20, +4.755
GND__1B1_A120afa8f2f-b656-47cf-88a4-6cb24ab613d0+3.20, +4.755
VBUSA4_B9da695063-5727-4f49-8ce4-455be6ec2bab-2.40, +4.755
VBUS__1B4_A9f3a778b5-7265-4041-a4f7-6851fd7b1ad3+2.40, +4.755
CC1A543b270d3-c570-4ed5-9918-dddc2e4b6eaa-1.25, +4.755
CC2B5cd9c8ce5-718d-451f-8e8c-5326ba8fd1fe+1.75, +4.755
DP1A6558e9a7b-4270-4562-8152-a249dcf087da-0.25, +4.755
DP2B68a027c1c-bd90-4369-bd8d-a7671a56b90d+0.75, +4.755
DN1A719b656a0-2310-4faf-b770-1ef899d075fb+0.25, +4.755
DN2B739939b32-5ada-47ec-88b0-6e9a3c12e996-0.75, +4.755
SBU1A8e2bac5e4-3e22-4607-b015-ff18df4d7be9+1.25, +4.755
SBU2B8fb8c14fa-da10-4b4a-97fc-5045185b0395-1.75, +4.755
SHELL_GNDSH11aedeb47-c039-4407-8288-a370f6ff6caa-4.32, +4.18
SHELL_GND__1SH27bef78f6-62a3-447f-9955-54687584a179+4.32, +4.18
SHELL_GND__2SH389328964-4719-4fef-aad3-32f9ae2d24df-4.32, 0
SHELL_GND__3SH4fc558013-b46e-479c-99ad-5d66111e27b4+4.32, 0
Footprint UID: e144d1e5-c996-4a7a-a01d-8049d0ab61fd.defaultFootprint; asset FP_GCT_USB4105-GF-A. Its literal KiCad asset contains one A1_B12 pad and one B1_A12 pad, each 0.60 × 1.15 mm on F.Cu/F.Mask/F.Paste with solder-mask margin 0.102 mm. No duplicate or coincident GND asset pad exists. No geometry was altered. Four shell stakes and two nonplated locating holes remain unchanged. This is not a complete manufacturer mask/paste or shell-geometry qualification; the investigation preserves the existing geometry rather than asserting a new qualification.
Verification evidence
  • get_schematic(full) and get_schematic(metadata): all 16 terminal elements read exhaustively; zero nets, zero wires, zero no-connects.
  • get_layout(tree, rules=both): complete source tree and embedded footprint asset read; 16 electrically mapped pads plus two locating holes; no reported UID suffixes; two distinct GND pads rather than four adjacent halves.
  • Published-part-reference read for UID e144d1e5-c996-4a7a-a01d-8049d0ab61fd: same 16-terminal composite mapping.
  • get_symbol(pins): 16 symbol pins including all four independent SH1–SH4 shell terminals.
  • Fresh checks at 2026-10-19T14:47:56.643Z: Missing Terminals Success, Excluded Terminal Success, zero errors/warnings in those two available reviews. Airwire/overlap/floating-copper/invalid-pad checks were requested but not returned for this part-only project; this is not a zero-DRC assertion.
  • Fresh get_layout(routing_state, includeComputedCopper=true): Airwire check result is unavailable; Redundant trace check result is unavailable. Remaining airwire count is unknown, not zero.
  • get_project_diff against baseline a76dae05 before this document write returned “Base and target resolve to the identical project version,” corroborating no design mutation.
Safe next action / workaround limits
Obtain the affected board project URL, connector designator, instance part UID/version, full flagged node UIDs, routing-state output and applied overrides. Compare its actual instance mapping with the table above. If that instance uses an older/different four-ground-terminal footprint, updating or replacing it with a verified composite-pad version is a candidate workaround, but pin remapping must preserve all GND/VBUS pairs, USB signals and SH1–SH4 nets; it is not yet tested or applied. Do not blindly publish or replace the part, and do not suppress the airwires.
If the actual board already has these composite pads and exported same-net copper is continuous while its connectivity engine still reports the two islands, escalate as a reproducible platform connectivity issue with that board's exact state. Current evidence is insufficient to claim that diagnosis or prescribe via deletion.
Drawing inspection artifact
Original manufacturer PDF inspected: https://gct.co/files/drawings/usb4105.pdf (sheet 1, drawing revision B8 as rendered). Download/render command completed successfully. The renderer below was used to distinguish contact labels from shaded PCB solder areas.

usb4105-drawing

  • Status and scope

  • Findings and root-cause limits

  • Exact mappings before and after

  • Verification evidence

  • Safe next action / workaround limits

  • Drawing inspection artifact