Fix Schurter Footprint Geometry
Complete missing part properties and create a datasheet-matched LSH gullwing package model.
Verify metadata and inspect the attached model’s dimensions, seating, and lead alignment.
9c36f6be), read back successfully:Table
| Canonical property | Value |
|---|---|
| Manufacturer Name | SCHURTER |
| Manufacturer Part Number | 1301.9314 |
| Datasheet URL | https://www.vniva.com/pdf-d5/1301.9314.pdf |
| Product Info Url | https://www.schurter.com/en/part/1301.9314 |
| Mount | Surface Mount |
| Package or Case Code | 4-SMD |
| Voltage Rating | 12 V |
| Current Rating | 0.05 A |
| Operating Temperature | -20°C to 70°C |
Part Type = Switch and Designator Prefix = SW were preserved. The project-property tool warns these component-category properties are nonstandard on a general project, but accepts the canonical keys on this part project; subsequent part review recognizes them and passes. SCHURTER is absent from the autocomplete list but its exact manufacturer name was retained rather than substituted.0e92989b-5e35-ca54-ed72-01ae77f3925c, 0f8800e5-8079-1d71-34ca-51be810f830a) now have Pin Type = Passive and Pin Description = Normally open switch contact (commit 578086b8). Pin numbers, symbol placement, terminal associations and pad geometry were not modified. Schematic readback confirms both properties on both terminals.datasheet-check:/root/work/switch/datasheet.pdf. The original page-2 LSH mechanical drawing was visually inspected at high resolution (not inferred from pad size). Its body height label is 3.6 mm; lead thickness 0.3 mm; toe-to-toe span 10.00 mm; lead width 0.7 mm; lead-row spacing 4.50 mm.lsh-mechanical-detail
df755c83-21b2-4bce-b111-3d86336ff2ed) with symbol/footprint assets but no 3D model. Ultra Librarian likewise explicitly reports no 3D model for that packaging variant. No claim that a vendor CAD model does not exist is intended—none was obtained.fd53a204-b7e4-67a2-27ab-81dc46af92dd still references asset 3D, storage SW_PUSH_6mm-0476950c-f3db-0a9a-9987-97aca8310164.step, under ROOT. It is incorrect for this LSH part; left unchanged because replacement was authorized only after successful generation. It must not be treated as verified geometry.9c19630a-3c24-bc2a-cb37-73876b5fa423. Its future centered source should be placed at footprint-local (3.25, -2.25, 0) mm, rotation (0,0,0), unity scale, with lead soles on z=0 and four gullwing feet aligned with the corrected lands. This placement has not been applied or render-verified.FOOTPRINT_V5 still embeds the Omron through-hole geometry, and its old silk crosses corrected lands. The self-preview SW1 retains its prior instance datasheet URL; the part-project root has the verified accessible archive URL. No overall production-readiness or publication claim is made.Scope outcome
Changed properties and verification
Model research and precise blocker
Preserved configuration and remaining release blockers