Fix Schurter Footprint Geometry


I’ll fill in the missing properties from the Schurter datasheet and generate the LSH gullwing 3D model, then check its size, seating, and lead alignment against the footprint.
Thought for 8 mins 27 sec
Thought for 8 sec
1/2 Complete missing part properties and create a datasheet-matched LSH gullwing package model.

Complete missing part properties and create a datasheet-matched LSH gullwing package model.

Verify metadata and inspect the attached model’s dimensions, seating, and lead alignment.

Thought for 20 sec
Awaiting 1 task
Thought for 7 sec
Reading "metadata-and-model-evidence" project doc.
"SW Push Part Metadata and 3D Model" completed.
Completed the missing properties; both metadata checks now pass—details are in Metadata and Model Evidence. The exact 3D model is blocked because the datasheet leaves actuator diameter and lead-bend details unspecified, so no replacement was attached. May I generate a clearly labeled nominal visual model, or can you provide the manufacturer’s STEP file?
its all good now, i already imported the 3D model from the manufacturer
Understood—the manufacturer’s 3D model resolves the model-generation blocker. I’ll leave your imported model and alignment unchanged.

Footprint Repair Evidence
Status — partial repair; NOT ready to publish
Project: /adrian95/swpush. Scope was source footprint repair for Schurter 1301.9314, not changes to any consuming board. No publish was performed.

Table


Assigned itemStatusEvidence / blocker
Inspect source ownershipCompletedFour pad nodes under source Footprint, with no element ancestor. Two left pads are terminal-derived; two right pads are standalone.
Source dimensions and contact pairingCompleted by manual PDF inspection; immutable citation verification unavailableManufacturer drawing was downloaded from an archived copy and rendered. Official URL query still reports evidence_pending/unverified; no immutable citation ID was issued.
Four proper SMD landsCompleted geometricallyFresh layout tree shows exactly four active rectangular Top SMD pads, each 2.10 mm X × 1.40 mm Y, rotation 0°.
Remove unintended via/drillsCompleted in effective layoutVia removed; all four pads explicitly SMD and holeSize=0mm; filtered tree contains only four pads, no via/smartVia/routeSegment.
Correct electrical pairingFailed / blockedRight-hand standalone pads have no source terminal association. Exposed tools cannot bind an existing standalone source pad to a terminal; add_pad terminalId is documented only for element-parent placed components. Do not infer mapping from pad names or shape.
Source updateCompleted for effective native pad-node rules; raw imported asset unchangedDirect source node rules, not !important selector overrides. Legacy FOOTPRINT_V5 asset remains the old THT KiCad source.
Existing review issue closureUnattemptedNo defect-specific issue ID found. Do not resolve the defect while terminal association is uncorrected.
Internal part-quality reportCompletedExactly one part_quality_issue report filed successfully; do not duplicate.
Manufacturer evidence
Official product page discovered: https://www.schurter.com/en/part/1301.9314
Official datasheet URL discovered: https://www.schurter.com/en/datasheet/typ_6x6_mm_tact_switches.pdf (direct retrieval returned 403; immutable datasheet lookup remains pending).
Manufacturer-authored PDF copy actually downloaded and read: https://www.vniva.com/pdf-d5/1301.9314.pdf, SCHURTER “6x6 mm tact switches,” dated 25.07.2018, page 3 “LSH Gullwing lead” and variants table. The following physical facts were visually read from this PDF; they are unverified by the immutable datasheet citation service, not guessed from the failed query:
  • 1301.9314 is LSH gullwing, 4.30 mm overall height.
  • LSH lands are 2.10 mm horizontally × 1.40 mm vertically, at 10.00 mm horizontal and 4.50 mm vertical center pitch.
  • The circuit diagram pairs upper pins 1–2 and lower pins 3–4. Actuation connects those two groups.
  • Four SMD lands, no drilled holes in the LSH land pattern.

lsh-land-pattern

The above pattern is distinct from LSG and from the original Omron-derived 6 mm through-hole footprint.
Exact native source state after edits
Source footprint UID: 9c19630a-3c24-bc2a-cb37-73876b5fa423.
Existing body center preserved at (3.25, -2.25) mm; therefore the land centers are offset from the project origin, not centered on (0,0). Equivalent body-centered coordinates are X=±5.00 mm and Y=±2.25 mm. All values below are project/source-footprint coordinates in mm, X right and Y up.

Table


Native pad UIDXYX sizeY sizeLayerRotationPad type / holeActual terminal associationRequired electrical group
0e92989b-5e35-ca54-ed72-01ae77f3925c-1.750.002.101.40Top0°SMD / 0mmExisting symbol terminal 1Upper manufacturer pins 1–2
2ac4f923-9620-4e7c-f1fa-86bd119baf9f8.250.002.101.40Top0°SMD / 0mmNone: standalone source padMust join symbol terminal 1
0f8800e5-8079-1d71-34ca-51be810f830a-1.75-4.502.101.40Top0°SMD / 0mmExisting symbol terminal 2Lower manufacturer pins 3–4
34ad394e-e078-f406-18d9-2e987e53d35d8.25-4.502.101.40Top0°SMD / 0mmNone: standalone source padMust join symbol terminal 2
Left generated-pad parent is 9c19630a-3c24-bc2a-cb37-73876b5fa423.Pads; right standalone-pad parent is the footprint UID itself. The original 2-pin symbol was preserved, with its original terminal UIDs, pin numbers, and pin positions.
Deleted via: 33c85dae-c42f-92a8-47de-c59f01e97c13, originally at (0,0), 0.60 mm annulus/0.30 mm through hole.
Edits
  1. On all four existing source pad nodes: padShape=rectangle, padHoleType=SMD, size=2.10mm 1.40mm, rotation=0deg 0deg 0deg, holeSize=0mm, layer=Top, forceAnnularLayers=Connected only. Removed old sizeX/sizeY local rules.
  2. Left column positionX=-1.75mm; right column positionX=8.25mm; preserved row Y coordinates 0 and -4.50mm.
  3. Set explicit rotationZ=0deg on both terminal-derived pads after readback caught inherited 90° asset rotation overriding the rotation vector. Final readback confirms all four computed rotations zero.
  4. Deleted the erroneous via.
  5. Attempt to replace the legacy generated silk line with a 6×6 mm body outline failed with “Unknown pcb node uid”; no silk change occurred. Legacy outline intersects the relocated pad region and needs cleanup through source asset editing or supported generated-node editing.
Verification and remaining issues
  • Final get_layout tree filtered for pad/via/smartVia/routeSegment returns exactly four pads, no vias or traces, each computed size 0.0021×0.0014 m and zero rotation.
  • get_symbol confirms exactly two unchanged symbol pins.
  • DRC post-mutation checks repeatedly return NOT CHECKED for Invalid Pads, Via In Pad, Overlapping Copper, Invalid Layer, and other layout checks in this source part. This is not a clean DRC result.
  • Fresh project review at 2026-10-21T07:26:57Z reports two pre-existing ERC errors (floating SW1:1 and SW1:2) and three pre-existing project metadata warnings (missing manufacturer, MPN, datasheet URL). Those unrelated schematic/metadata items were left unchanged.
  • Original FOOTPRINT_V5 still contains THT (drill 1.1) records and Omron description. Native source rules override the four effective pads, but the archival asset itself was not rewritten.
  • Original SW_PUSH_6mm model and useful symbol were preserved. The THT-looking model is not verified for Schurter LSH and should not be treated as corrected.
  • Electrical pairing is the release blocker. Do not publish or close the defect based solely on the corrected copper geometry. Required next capability: associate the two existing standalone source pads with the two existing terminals (upper-right → terminal 1; lower-right → terminal 2), or perform a supported source-footprint import that preserves the two-terminal symbol and correctly binds duplicated lands. Verify those associations from actual source data afterward.
The task batch is finished with partial results; the overall definition of done has not been met.
  • Status — partial repair; NOT ready to publish

  • Manufacturer evidence

  • Exact native source state after edits

  • Edits