64900001039 Fuse Holder Guide


I’ll research the fuse holder’s manufacturer documentation and verified alternatives, then create a cited application and usage guide in the project files.
I confirmed the component is Littelfuse’s 649-series 5 × 20 mm PCB fuse block. Older listings disagree on its material and temperature range, so I’m checking the current datasheet; that lookup is still running while I verify alternatives and sourcing.
I’ve finished the source research and found two functional alternatives, but neither is a qualified drop-in replacement. I’m saving the guide with direct source links and explicit verification flags because the automated datasheet lookup did not complete.
Created a project doc

64900001039 Application and Usage Guide

View Document

64900001039 Application and Usage Guide
The Littelfuse 64900001039 is a non-indicating, PCB-mounted fuse block for a replaceable 5 × 20 mm cylindrical cartridge fuse, catalog-rated at 6.3 A and 250 V AC/DC (manufacturer product page). Its common integration is in series with an equipment power input to retain a separately selected fuse that provides overcurrent protection; the holder itself does not establish a trip current ([Littelfuse holder-selection guidance](https://www.littelfuse.com/products/fuses-overcurrent-protection/fuse-holders-fuse-b...
Created and checked the 64900001039 Application and Usage Guide in the project files, covering all seven requested sections with source links, practical wiring and layout guidance, alternatives, and purchasing details. Datasheet-only values are explicitly flagged because automated verification did not complete, and neither alternative is presented as a qualified drop-in replacement. Before design release, validate the footprint against the manufacturer drawing and qualify the selected fuse/holder combination thermally.

64900001039 Application and Usage Guide
The Littelfuse 64900001039 is a non-indicating, PCB-mounted fuse block for a replaceable 5 × 20 mm cylindrical cartridge fuse, catalog-rated at 6.3 A and 250 V AC/DC (manufacturer product page). Its common integration is in series with an equipment power input to retain a separately selected fuse that provides overcurrent protection; the holder itself does not establish a trip current (Littelfuse holder-selection guidance).
Scope: Practical schematic integration, 5 × 20 mm fuse selection, through-hole PCB layout, replacement qualification, and purchasing. Research date: October 7, 2026. No symbol, footprint, or PCB geometry was modified or qualified during this documentation task.
Verification status: Manufacturer product-page facts and distributor ordering facts below were checked directly. U — unverified labels identify values reported by the linked current manufacturer PDF whose automated citation-backed datasheet verification did not complete; they are disclosed source transcriptions, not independently verified design-release inputs. Engineering recommendations are labeled separately. Missing or ambiguous facts are not filled with assumptions.
1. Quick Specifications
A fuse holder uses rated voltage, current, and accepted-power limits rather than an IC-style operating supply range. Do not treat its catalog current rating as a guaranteed continuous-load capability at every ambient temperature; Littelfuse explains that fuse-link heating and installation conditions affect holder selection (selection guidance).

Table


ParameterPublished value and verification statusRating classification / practical meaning
Manufacturer / seriesLittelfuse / 649; confirmed by manufacturerExact ordering number: 64900001039.
Maximum AC voltage250 V AC; confirmed by manufacturerPublished rated limit, not a recommended design target or an assembly safety certification.
Maximum DC voltage250 V DC; confirmed by manufacturerThe installed fuse must separately have an adequate DC voltage and interrupting rating.
Current rating6.3 A continuous catalog rating; confirmed by manufacturerHolder rating, not fuse operating or trip current. Final allowable load is installation-dependent.
Maximum current / powerU: PDF reports 6.3 A / 1.6 W under “Electrical Data” (current datasheet)The power figure concerns fuse/holder thermal compatibility, not the electrical power delivered to the load; see manufacturer's accepted-power explanation.
Compatible fuse5 × 20 mm cylindrical cartridge; confirmed by manufacturerNominal fuse envelope, not terminal pitch. Fuse must be ordered separately unless a supplier explicitly provides an assembly.
Package / mountingPCB mount, through-hole PC-pin termination; confirmed by manufacturer and DigiKeyMolded fuse block; two electrical connections in the current Flux part.
Terminal spacingU: part drawing reports 15 ± 0.1 mm; PCB hole drawing reports 15 mm +0.25/−0 (datasheet, Dimensions)Keep component-lead tolerance and board-hole tolerance distinct; review the original drawing before footprint release.
Operating temperatureU: −30 °C to +85 °C (datasheet, Product Specifications)Published operating range, not proof that full rated current is usable throughout it.
Contact resistanceU: ≤ 5 mΩ (datasheet)Measurement conditions and whether this represents one interface or the complete holder path were not established; do not infer a guaranteed total-path voltage drop.
Body / contactsU: tan PA66 thermoplastic, UL94 V-0; tin-plated copper-alloy metal parts (2023 datasheet)Older catalog copies describe white PBT; confirm material and document applicability to the purchased lot if this affects compliance.
Recommended operating currentNo part-specific, validated current-versus-ambient curve was obtainedDetermine from fuse dissipation, maximum enclosure ambient, PCB copper, airflow, and temperature-rise testing; a universal numeric operating recommendation is not established here.
Separate absolute-maximum table / typical valuesNo separate, validated absolute-maximum or typical-performance table was obtainedThe rated limits above are not a substitute for transient withstand, fault containment, or thermal qualification.
Assembly limits reported by the PDF — U: solderability 235 °C for 2 seconds and soldering-heat resistance 260 °C for 10 seconds, both solder-bath tests under IEC 60068-2-20 (datasheet). These tests are not permission to expose the whole component to an arbitrary reflow profile.
2. Pinout & Connections
The following numbering and P1/P2 names are confirmed from the current Flux symbol, not manufacturer-designated IN/OUT labels. The physical device is a passive fuse block without a polarity-dependent function; the manufacturer's drawing does not establish a directional input/output pinout.

Table


Pin NumberPin NameDescriptionBest Practice
1P1One fuse end contact; electrical terminal in the current Flux partAs a schematic convention, connect to the incoming power conductor that requires protection. Locate the unfused segment close to the input connector.
2P2Other fuse end contact; electrical terminal in the current Flux partAs a schematic convention, connect to the protected power net feeding the load. Do not copper-short this pin to P1 around the fuse.
—Plastic locating studU: the PDF reports a plastic stud in addition to the solder pins (datasheet)Mechanical feature only; not a third electrical pin. Its hole is not a ground connection.
Engineering guidance: No pull-up, pull-down, enable connection, signal ground, or bias supply is required. Do not connect either electrical pin to GND unless a separately analyzed protection topology explicitly requires a fused return; simply copying IC pin-connection advice is inappropriate for this part.
3. Standard Application Circuit
Engineering recommendation — basic positive-rail input protection:

Text


Input connector + ── P1 [64900001039 + selected 5 × 20 mm fuse] P2 ── VIN_PROTECTED ── Load
Input connector − ──────────────────────────────────────────────────────────────── Return
The two holder contacts connect the separately installed fuse in series with the power conductor. Without an installed conductive fuse, the intended protected path is open; a blown fuse interrupts it. This is a connection example, not a selected fuse or a validated product schematic.
Required component: one suitable 5 × 20 mm cartridge fuse. There is no mandatory resistor, capacitor, inductor, or semiconductor needed merely to operate this passive holder. Downstream decoupling, surge suppression, reverse-polarity protection, and inrush limiting belong to the load/input-protection design, not to the fuse holder itself.
Select the fuse and holder together: Littelfuse identifies current, voltage, interrupting rating, physical size, and indication as selection considerations and explains the significance of fuse-link heat dissipation (manufacturer guidance). For the actual application:
  1. Select fuse current and time-current characteristic from maximum normal load, startup/inrush pulses, ambient conditions, and the protected conductor/component limits. A holder marked 6.3 A does not mean the correct fuse is automatically 6.3 A.
  2. Verify the fuse voltage rating for the actual AC or DC system and its interrupting capacity against prospective fault current at the installation point. A 250 V AC fuse rating must not be assumed to confer the same DC capability.
  3. Verify the fuse-link power loss against the holder's accepted power and actual thermal environment. The PDF's reported 1.6 W value is U, pending citation-backed verification; use confirmed manufacturer documentation before release.
  4. Place input bulk capacitance on the protected side when it is part of the load, but include its charging current in fuse/inrush analysis. This is engineering guidance, not a Littelfuse-mandated capacitor value.
  5. For a grounded DC supply, positive-rail placement is the usual starting topology. For mains equipment, protect the line/live conductor as required by the applicable equipment standard; reversible supplies or multi-pole systems need separate analysis. Never fuse protective earth. This generic example does not qualify a mains-powered assembly.
Derating caution: Littelfuse's general holder page contains both a rough 30%-of-UL-rating real-application statement and a separate 60%-of-UL-rating recommendation at 25 °C (source). Those are not cumulative deratings, are not interchangeable with an IEC accepted-power rating, and do not establish a verified operating-current limit for this exact holder/fuse combination. Obtain part-specific guidance or test the installed combination rather than mechanically applying either percentage to 6.3 A.
4. PCB Layout & Routing Guidelines
  • Confirm all mounting geometry, not just two pads. U: the manufacturer's PCB drawing reports two electrical holes Ø1.3 ± 0.05 mm, a locating hole Ø2.6 mm +0.05/−0, electrical-hole spacing 15 mm +0.25/−0, and PCB thickness 1.6 ± 0.14 mm (Dimensions drawing). Review the drawing for datum/orientation and define finished-hole versus fabrication-drill allowances with the fabricator. The existence and correctness of the mechanical hole in the current Flux footprint were not audited here.
  • Size the entire current path, including pad neckdowns and thermal spokes. U: the PDF reports a minimum conducting-path cross-section of 0.2 mm² (Product Specifications). Conditional engineering calculation: for a single rectangular copper path, width = cross-section / copper thickness; 0.2/0.035 = 5.714… mm for an assumed 35 µm copper thickness, or 0.2/0.070 = 2.857… mm for assumed 70 µm copper. Round up and use actual finished copper thickness. These are geometric checks, not thermally qualified trace widths or a justification for summing arbitrary parallel-layer paths.
  • Balance solderability and thermal performance. Engineering recommendation: use sufficiently broad, short connections or pours; avoid thin default thermal-relief spokes becoming the current bottleneck. Validate solder fill and joint quality if solid plane attachment requires more assembly heat. Verify temperature rise with the selected fuse under maximum normal load and worst enclosure ambient, not only with an idealized copper link (why dummy-fuse and real-fuse tests differ).
  • Prevent protection bypass and preserve insulation. Engineering recommendation: keep incoming and protected nets distinct on every layer; do not join them through a pour, test jumper, or unintended copper bridge. Determine mains/hazardous-voltage creepage and clearance from the applicable safety standard, pollution degree, material group, and overvoltage category; the holder voltage rating alone does not determine a safe PCB spacing. No universal clearance value is claimed here.
  • Allow safe servicing and separate heat-sensitive components. Engineering recommendation: leave access for fuse insertion/removal, keep nearby heat sources from raising contact temperature, and provide an appropriate enclosure or guarded access for exposed contacts. This part has no differential-pair routing requirement and no intrinsic decoupling requirement; keep downstream capacitors near the circuits they decouple rather than near this holder by default.
5. Common Pitfalls / Things to Watch Out For
  1. Treating 6.3 A as the fuse trip current or guaranteed usable load at any temperature. The holder and fuse are separate parts with different ratings; the real fuse generates heat, unlike a copper dummy used in some holder-rating tests (Littelfuse explanation). Select time-current behavior, fault interruption, and thermal compatibility together, then test the assembled circuit at worst-case ambient.
  2. Assuming every 5 × 20 mm holder has the same footprint or provides safe live servicing. Fuse size identifies the cartridge, not board-hole spacing, stud geometry, or access protection. Validate the original mounting drawing and replacement envelope; disconnect all power, address backfeed, and discharge stored energy before replacing the fuse. Never bridge a blown fuse with wire or fit a higher-current fuse without requalifying the protection design. These are engineering safety recommendations.
Two established manufacturer alternatives are shown below. No other-manufacturer drop-in replacement was qualified in this research. Electrical function similarity does not establish pin-number mapping, mechanical compatibility, thermal equivalence, or equivalent safety approvals.

Table


AlternativePrimary-source confirmationCompatibility classificationQualification required
SCHURTER OGN 0031.8201Manufacturer OGN variant table identifies a 5 × 20 mm THT holder, 22.5 mm terminal spacing, tin-plated terminals, and bulk packaging; see SCHURTER OGN technical page. These variant facts were checked on the manufacturer's webpage, not inferred from a distributor description.Functionally similar only; not footprint-compatible with a 15 mm footprint. Pin-number mapping has not been qualified.New footprint/envelope review, exact-version ratings and accepted-power review, and enclosure/cover assessment. Flux library entry exists, but its indexed MPN is incorrectly recorded as “SCHURTER Inc.”; verify metadata and footprint before use. Do not confuse 0031.8201 with packaging variant 0031.8201.G.
Eaton Bussmann HTC-60MEaton confirms PCB mounting for 5 × 20 mm ferrule fuses and lists IEC 60127-6 ratings of 6.3 A / 250 V and UL 4248 ratings of 20 A / 250 V on its product page.Functionally similar; footprint and pin compatibility unverified. Not represented as a drop-in.Compare the complete manufacturer HTC mounting drawing, including hole tolerances, locating features, board standoff, and body clearance. Revalidate thermal and certification requirements; the higher UL rating does not justify a higher load in the original design. No exact HTC-60M or BK-HTC-60M Flux entry was found.
The SCHURTER entry is linked to the identified Flux library part as a convenience, not as approval of its data or CAD. The Eaton link is to the manufacturer because no verified matching Flux entry was found. Stock levels for these alternatives were not checked; recheck before selecting them for a shortage response.
7. Sourcing & Purchasing Guide

Table


AttributeDetails
Primary DistributorsExact-part listings were confirmed for DigiKey, Mouser, and LCSC C206888. Additional purchase channel: TME. Check Littelfuse authorization for the supplier and shipping region rather than assuming every marketplace listing is franchised.
Packaging OptionsBulk is confirmed by DigiKey's exact-part listing. U: manufacturer ordering table reports “Bulk (3000pcs)” for 64900001039 (datasheet). No tape-and-reel or cut-tape option was verified.
Standard MOQ1 piece on the checked DigiKey listing. The PDF's reported 3,000-piece factory pack is not a universal distributor MOQ; factory-direct minimums and current order multiples must be confirmed at purchase.
JLCPCB Assembly RouteJLCPCB C206888 lists the exact holder as an Extended part. Its page states purchased components are for future PCBA orders and cannot be shipped separately. Confirm current inventory, through-hole assembly support, setup/assembly charges, and whether fuse insertion is a separate operation before ordering. A generic “Full Reel: 3000” field on that page does not establish physical tape-and-reel packaging when the manufacturer specifies bulk.
Ordering-Code ChecksOrder the complete 64900001039 code. U: the current PDF separately lists 64900003039 as a grey PA66 “MM GW” variant, also in bulk (ordering table). Do not silently substitute that variant or obsolete packaging codes; obtain confirmation of material, certification, geometry, and packaging requirements.
Sourcing AdvicePrefer manufacturer-authorized/franchised distribution with lot/date-code traceability and applicable compliance documentation. Treat counterfeit, reworked, aged, or incorrectly plated stock from untraceable marketplaces as a contact-heating and safety risk. Obtain the applicable material/revision information when distributor descriptions disagree with current primary documentation. Fuse, enclosure/cover, and holder are separate purchasing items unless explicitly bundled.
Stock and PriceAvailability and price are time-dependent; no quote or stock reservation is made by this guide. Distributor feeds differed during research, so compare current listings immediately before purchase rather than relying on a single cached stock number.
Sources
  • Littelfuse — 649 Series Fuse Block Datasheet, “Molded Fuse Block, PC Mount for 5×20mm Fuses”; document footer reports Revised: GD. 02/13/23, ©2023. Official manufacturer datasheet. Manufacturer PDF text was retrieved through a direct source read, but automated immutable citation verification did not complete; values from this PDF carry U labels. TME-hosted manufacturer copy was also attempted; its citation-backed lookup remained pending.
  • Littelfuse — 64900001039 official product page. Link. Primary source for catalog current, maximum AC/DC voltage, fuse size, mounting, non-indicating status, and active lifecycle. No webpage revision date displayed in the checked content.
  • Littelfuse — Fuse Holders selection guidance, including “Selection of the Fuse and Holder Solution” and “Rerating (Derating) a Fuse Holder.” Link. Primary source for IEC/UL rating distinctions, accepted power, and the separate 30% and 60% discussions. No publication/revision date displayed in the checked content.
  • SCHURTER — OGN official technical webpage and variant table. HTML technical data, manufacturer PDF, and 0031.8201.G variant page. The checked webpage displays transformation date 2025-09-01; this is webpage metadata, not an independently verified PDF revision. Only webpage-confirmed variant facts were used here.
  • Eaton — HTC-60M official product page. Link. Primary source for fuse size, PCB mounting, and separately specified IEC/UL ratings. Related document: HTC PCB fuse holder/clip data sheet, Technical Data 2110, search-reported Effective April 2024; supersedes July 2023. The PDF geometry was not fully qualified in this task and is linked for replacement verification, not as proof of interchangeability.
  • DigiKey — 64900001039 exact-part listing. Link. Distributor primary source for bulk packaging, active listing status, and quantity-one purchasing.
  • Mouser — 64900001039 exact-part listing. Link. Listing URL and availability confirmed through the Flux distributor feed; MOQ not independently checked.
  • LCSC — C206888 exact-part listing. Link. Exact supplier identifier and listing confirmed through the Flux distributor feed; no authorization claim made.
  • JLCPCB — 64900001039 / C206888 assembly listing. Link. Supplier primary source for Extended status and assembly-only component purchasing restriction.
  • TME — exact-part listing. Link. Distributor source for the exact ordering code; current availability must be rechecked.
  • Current Flux symbol and parts library inspection, October 7, 2026: 64900001039 pins 1/P1 and 2/P2 confirmed; SCHURTER 0031.8201 library entry identified with an MPN metadata mismatch. These are CAD/library observations, not manufacturer certifications.
  • 1. Quick Specifications

  • 2. Pinout & Connections

  • 3. Standard Application Circuit

  • 4. PCB Layout & Routing Guidelines

  • 5. Common Pitfalls / Things to Watch Out For

  • 6. Popular Alternatives & Equivalents

  • 7. Sourcing & Purchasing Guide

  • Sources