I found two alternatives in the Flux library, but matching pitch alone does not establish drop-in compatibility. The exact-part datasheet lookup is still unresolved; I’ll check the manufacturer’s family drawing and clearly flag any remaining gaps.
The Würth Elektronik 61300621121 is a WR-PHD straight, through-hole, six-contact male PCB header arranged as two rows of three on a 2.54 mm grid, as identified in the manufacturer product table. Its practical use is a detachable board-to-board or cable-to-board connection for low-voltage power and signals, with the signal assignments defined by the application rather than the connector.
1. Quick Specifications
Rating terminology: A passive connector does not have an IC-style supply rail or a typical supply current. The verified family drawing lists connector ratings,...
Created the 61300621121 Application and Usage Guide in the project files, covering all seven requested sections with citations and two linked Flux-library alternatives. Exact footprint details, drop-in compatibility, and purchasing quantities are explicitly flagged where verification remains incomplete.
The Würth Elektronik 61300621121 is a WR-PHD straight, through-hole, six-contact male PCB header arranged as two rows of three on a 2.54 mm grid, as identified in the manufacturer product table. Its practical use is a detachable board-to-board or cable-to-board connection for low-voltage power and signals, with the signal assignments defined by the application rather than the connector.
1. Quick Specifications
Rating terminology: A passive connector does not have an IC-style supply rail or a typical supply current. The verified family drawing lists connector ratings, not a separate “Absolute Maximum Ratings” table; do not reinterpret the dielectric test voltage as an operating limit.
Manufacturer connector rating, not a guaranteed simultaneous six-contact load at every ambient temperature.
Working voltage
250 V AC
Manufacturer working rating; not a safety approval for an exposed mains interface.
Dielectric withstanding voltage
500 V AC; family drawing notation “AC/MN”
Test rating, not continuous operating voltage; exact-part test duration remains unverified in the citation-backed lookup.
Operating temperature
−40 to +105 °C
Manufacturer operating range. Contact heating must be considered separately.
Contact resistance
20 mΩ maximum
Electrical characteristic, not a typical value.
Insulator resistance
>1,000 MΩ
Family drawing electrical characteristic.
Contacts
Copper alloy, gold plated
Material and finish.
Housing length
7.62 mm
Exact-part manufacturer product table; also derived from family formula B = 2.54 × (NB PINS/2) with NB PINS = 6.
Example design operating level
3.3 V or 5 V logic, application-dependent current
Engineering example only; neither is a manufacturer-required supply voltage.
Separate absolute maxima / current derating curve
Unverified
No such limits or curve were verified during this research. Obtain operating-condition-specific guidance before high-current qualification.
Evidence limitation: The exact-part PDF lookup remains unresolved. The manufacturer family drawing explicitly covers 6130xx21121 and supports the cited ratings; exact-part hole tolerances, complete physical numbering orientation, durability, and packaging quantities have not been citation-verified. Do not release a footprint from this guide alone.
2. Pinout & Connections
All six terminals are passive contacts; no terminal is inherently GND, VCC, reset, or an enable input. The table names contacts only and intentionally does not invent an interface assignment.
Table
Pin Number
Pin Name
Description
Best Practice
1
Contact 1
Application-defined connection
Identify pad 1 on the PCB and document its mating-side orientation.
2
Contact 2
Application-defined connection
Assign GND only if the selected interface requires it; never assume it is ground.
3
Contact 3
Application-defined connection
Check logic voltage and driver/receiver directions before assigning a signal.
4
Contact 4
Application-defined connection
Apply pull-ups or termination only when required by the connected circuit.
5
Contact 5
Application-defined connection
If used for power, check the complete header/socket/cable current path.
6
Contact 6
Application-defined connection
Leave unused contacts unconnected unless the interface specification requires otherwise.
Numbering warning: A complete manufacturer-verified top-view 1–6 map was not established. Match schematic terminal IDs to the actual footprint and mating connector drawing; the solder-side view is mirrored relative to the component-side view. Do not treat the order of rows in this table as a physical placement diagram.
3. Standard Application Circuit
The standard integration is direct net-to-contact wiring, followed by a compatible female socket or cable receptacle. The manufacturer family drawing identifies a dual pin header, not an active interface circuit.
Illustrative low-voltage expansion connection—not a Würth-standard pinout:
Text
MCU-board schematic Header contact Mating-board connection
3.3 V rail 1 3.3 V rail, if power is shared
GND 2 GND
MCU output A 3 Receiver input A
MCU input B 4 Driver output B
MCU output C 5 Receiver input C
Unused 6 No connection
Engineering integration recommendations:
No resistor, pull-up, capacitor, or termination is required merely to operate the header. Add these parts for the circuits attached to it, not for the connector itself.
For a powered daughterboard, place its IC decoupling capacitors at the IC power pins and choose local bulk capacitance from the load-step and source-impedance requirements; there is no verified universal capacitor value for this header.
If two boards have independent supplies, do not directly connect their rail outputs without a deliberate power-path design. Connect compatible signal references and check input tolerance, back-powering, and power-off behavior.
Use a mating socket whose pitch, row spacing, contact acceptance, engagement depth, plating, and current rating are suitable. Mechanical fit and the lower of the two connector ratings govern the assembly.
For externally accessible connections, select ESD protection from the actual signal and exposure requirements. Avoid assuming hot-plug capability or ground-first mating.
LED resistor calculations, USB-C CC pull-downs, and shield connections are not applicable: this is neither an LED nor a USB connector.
4. PCB Layout & Routing Guidelines
Footprint and drill: Use the manufacturer’s two-row 2.54 mm grid. Confirm the finished plated-hole diameter against the current exact-part drawing and JLCPCB’s drill/plating tolerances. The exact-part web extraction reported Ø1.10 ±0.15 mm, while the legacy-family extraction returned a different, unsupported hole claim; therefore the hole diameter is unverified and neither is released here as a footprint instruction.
Orientation and access: Mark pin 1 and the connector net labels on silkscreen; leave clearance for the complete socket body, insertion/removal motion, and adjacent component heights. An unshrouded connector should not be relied upon for polarization.
Current paths: Size traces, plated holes, vias, and plane neck-downs from actual current, copper thickness, and acceptable temperature rise—not from pitch alone. The connector is rated 3 A, but no application-independent trace width or all-pins-loaded derating was verified.
Thermal relief and assembly: Choose thermal relief on plane-connected THT pads to obtain reliable solder fill, but verify that the spoke geometry carries the intended current. The family drawing specifies a JEDEC lead-free wave-soldering process; an SMT reflow process is not established by that statement.
Signal integrity and decoupling: Keep signal return paths continuous. If carrying a differential pair, route to the interface’s impedance/skew targets and assess the header and socket discontinuity; no controlled-impedance or bandwidth guarantee was verified. Put load decoupling at the receiving ICs rather than automatically beside every header contact.
5. Common Pitfalls / Things to Watch Out For
Mirrored or reversed pin assignments. A matching two-row footprint does not guarantee that a cable assembly, schematic symbol, and mating socket share the same numbering orientation. Verify pad-to-contact correspondence and continuity on the first assembly; use clear orientation labels or a keyed connector where reversal would damage the circuit.
Confusing component ratings with system capability. The 250 V AC working rating is not permission to expose mains on accessible pins, and the 500 V AC withstand figure is a test rating. Similarly, qualify current with the socket, cable, PCB, ambient temperature, and number of loaded contacts; do not assume every pin can carry its nameplate current simultaneously.
6. Popular Alternatives & Equivalents
Both parts below were found in the Flux library. Neither is claimed as a verified drop-in replacement: full mating-stack, numbering, tolerance, plating, and electrical qualification remain necessary.
Exact manufacturer page identifies six pins, two rows, THT, 0.100 in pitch, 0.230 in mating post, and 0.430 in overall length. Its recommended PCB holes are 1.02 mm on a 2.54 mm grid.
Functionally similar; nominal pin-grid compatible. Footprint compatibility unverified. Check finished holes, pin numbering, post length, socket engagement, and actual electrical rating.
Flux exact-MPN library record identifies six contacts; manufacturer family drawing verifies a straight double-row 2.54 mm header. The H-style drawing lists a 5.84 mm mating length and 3.05 mm tail; its recommended hole pattern uses 1.02 mm holes on a 2.54 mm grid.
Functionally similar; nominal pin-grid compatible. Footprint compatibility unverified. Exact 06 ordering-field interpretation was not independently validated by the datasheet lookup; compare the configured part drawing before substitution.
Do not transfer the Würth current, voltage, temperature, or durability limits to either alternative. Qualify the complete mated assembly and update the BOM to the exact manufacturer ordering code.
7. Sourcing & Purchasing Guide
Table
Attribute
Details
Primary Distributors
Exact-part listings were returned by the Flux distributor lookup for DigiKey, 732-5295-ND and Mouser, 710-61300621121. Check the manufacturer's current authorized-distributor list for the purchasing region. LCSC availability for this exact Würth MPN was not verified.
Packaging Options
BAG is verified in the family drawing. Tape-and-reel and cut-tape options were not verified; do not use generic SMT packaging assumptions.
Standard MOQ
Unverified. Search context suggests distributor sales from one unit and exact-part factory bags of 1,000, but the distributor page could not be read and those quantities were not citation-verified. Confirm MOQ, order multiple, and factory-pack quantity on the current quote; factory-pack quantity is not necessarily MOQ.
Sourcing Advice
Prefer the manufacturer or authorized/franchised distributors for traceable stock and consistent plating. Avoid untraceable marketplace substitutes; the larger risk for commodity headers is unspecified contact finish and inconsistent dimensions. Order exactly 61300621121 and verify that any proposed suffix/change preserves six contacts, dual rows, straight THT geometry, finish, and packing requirements.
Availability / pricing
Distributor lookup returned purchasable listings during research on 2026-10-07. Stock and prices are volatile, not a reservation or quote; confirm at checkout.
Sources
Würth Elektronik:61300621121 exact-part datasheet. Web extraction reports revision 001.001 dated 2020-06-08; this metadata and the exact-part geometry remain unverified by the citation-backed lookup, which is still unresolved.
Würth Elektronik:6130xx21121 family technical drawing, covering the target ordering-code family. Citation-verified revision I dated 16-JUN-15. This is the source of the inline electrical-rating and family-layout citations.
Distributor evidence: Flux exact-MPN distributor lookup returned the DigiKey and Mouser listing URLs above. DigiKey's direct page was unavailable; MOQ is explicitly unresolved rather than asserted from a search snippet.