| Item | Status | Evidence / blocker |
|---|---|---|
| J1 CC1/CC2 access | Failed | Shifted R1/R2 from X=17 to X=15.5 mm, retaining Y=-1.25/+1.75 mm and Bottom. Preflight remained 27, including both CC pins. Restored originals to avoid unnecessary placement changes. |
| U2 named pin access | Failed | All ten specified pins remain inaccessible after neckdown regeneration. U2/support placement edits unattempted: footprint-pitch versus clearance conflict is the leading blocker, not established external passive congestion. |
| U3 named pin access | Failed | All seven specified pins remain inaccessible. U3/L1/C5–C8 placement edits unattempted to preserve the validated stage; investigate the common fine-pitch rule conflict before disturbing it. |
| U4 named pin access | Failed | All eight specified pins remain inaccessible after neckdown regeneration. U4/support placement edits unattempted for the same common footprint/rule concern. |
| Preserve switching-power-stage geometry | Completed | No U3, L1, C5, C6, C7, or C8 movement. Fresh selected checks returned no Switching Power Stage findings. This is placement validation, not routed-current-loop validation. |
| Regenerate neckdowns | Completed | Tool regenerated two custom-shape neckdowns, commit #13c92799; preflight count unchanged. These replace the previous two neckdown nodes, rather than adding routed nets. |
| Preserve fixed objects, zones and 23/17 distribution | Completed for unchanged placement | Final full component readback equals initial positions/rotations/layers. No outline, connector, switch, LED, U1, or zone edits. |
| Preserve U2 duplicate-mount workaround | Completed | Ruleset 9738f1fe-3339-4b84-9524-bc6fdb62e5ef remains untouched, targeting five mount-pad nodes with active=false !important. |
| Overlap, outside-board, edge and existing-keepout checks | Completed for represented geometry | Final move reports overlaps=0, keepout violations=0, out-of-bounds=0. Read-only checks at 2026-09-17T00:47:45.677Z return no body overlap, copper overlap, outside-board, edge-placement, keepout, pad-access or power-stage findings. |
| RF keepout certification | Failed / outside this batch | Prior Placement Review records missing authoritative antenna keepout geometry. No RF objects were altered; zero returned keepout findings do not certify an unrepresented exclusion. |
| Zero inaccessible-pin done criterion | Failed | Final preflight: 27 warnings, unchanged from baseline. No unavoidable board-size limitation established. |
| Commit/report | Completed | Neckdown regeneration #13c92799, trial R1/R2 move #eb8593c1, restoration #89b745fe verified in history and diffs. Only two component-rule paths were modified by each placement call. |
| Route traces | Unattempted, intentionally | Neither routing tool was called; only explicitly permitted neckdown regeneration was used. |
Pad clearance (NPTH proxy) applies indiscriminately to pad, with keepOut=0.40 mm and minKeepOut=0.30 mm. Other profile rules include pad-to-pad minimum 0.50 mm and hole-to-trace 0.40 mm, likewise broadly selected. Net traceWidth=0.25 mm, minimum 0.20 mm; net clearance=0.25 mm, minimum 0.20 mm.Table
| Part | Pad pitch | Narrow pad dimension | Gap to equal neighboring pad |
|---|---|---|---|
| J1 CC neighborhood | 0.50 mm | 0.30 mm | 0.20 mm |
| U2 perimeter | 0.50 mm | 0.26 mm | 0.24 mm |
| U3 side rows | 0.50 mm | 0.30 mm | 0.20 mm |
| U4 perimeter | 0.50 mm | 0.28 mm | 0.22 mm |
Result — 2026-09-17
Disposition by scope item
Specific residual pins
Leading blocker: fine-pitch footprint versus global clearance rules
Recommended next scoped action